For AF40-A AF, AW only (Except AF10-A, AF50-A, AF60-A, AW10-A) 35 mm reduction New New Body size 10, 50, 60 added!
/030-A-20-R . 9-6 9.4 Cooling capacity . 9-7 9.4.1 HRS018-A-20--R . 9-7 9.4.2 HRS030-A-20--R . 9-7 9.5 Heating capacity . 9-8 9.5.1 HRS018-A-20-R, HRS030-A-20-R . 9-8 9.6 Pump capacity. 9-9 9.6.1 HRS018-A-20-R, HRS030-A-20-R . 9-9 9.6.2 HRS018-A-20-T-R, HRS030-A-20-T-R . 9-9 9.7 Compliance . 9-10 9.8 Sample DoC. . 9-11 9.9 Daily Check Sheet . 9-12 Chapter 10 Product Warranty . 10-1 HRS-R
9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018-10-MT 0.8 80 0.7 70 Circulating fluid pressure [MPa] 0.6 60 0.5 Pump head [m] Available area 50 0.4 Outlet60Hz 40 0.3 30 Outlet50Hz 0.2 20 Return port 0.1 10 Available area 0.0 0 0 5 10 15 20 25 5 Circulating fluid flow [L/min] Fig 9.6-3 Pump capacity(HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT) 9.6.4 HRS012--20-T, HRS018
(In such a case, use a bypass piping set (sold separately).) 8 Purchase an earth leakage breaker with current sensitivity of 30 mA separately. 9 Front: 1 m, height: 1 m, stable with no load, Other conditions See 3. 10 Weight in the dry state without circulating uids 9
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS018-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
integrated with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Main Board HRS018
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: F (G with PT-G conversion Fitting Set), Option: None
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-lift Pump)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BT (B + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]