SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-AN-20-JM"

Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized.

Applicable bore A 0.51 D C 1/4-28 UNF B 0.16 JM-025 0.44 3/4", 7/8" JM-03 0.50 0.19 5/16-24 UNF 0.50 1 1/16" JM-045 0.69 0.79 0.26 7/16-20 UNF 1 1/4", 1 1/2" JM-04 0.56 3/8-24 UNF 0.65 0.23 1 1/4", 1 1/2" (Non-rotating) JM-05 0.75 1/2-20 UNF 0.32 0.87 2" 6-14-20 21 Series NCM Mounting Bracket Accessory Material: Rolled steel P dia.

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: J + M

TROUBLESHOOTING Alarm No.: 20 Name: Encoder normal communication error 1 Alarm content An error occurred in the communication between an encoder and driver. Detail No.

TROUBLESHOOTING Alarm No.: 20 Name: Encoder normal communication error 1 Alarm content An error occurred in the communication between an encoder and driver. Detail No.

North American type Made to Order Basic type Bore size (inch-Nominal) Stroke/Hundredths of an inch 6 1/4" Stroke/Inch 10 3/8" 15 5/8" 20 3/4" 25 1" 32 1-1/4" 40 1-1/2" 50 2" 63 2-1/2" Standard Stroke Bore size Standard stroke (inch) Max. stroke (inch) (mm) (inch-Nominal) 2, 3, 4, 5, 6, 8, 10 2, 3, 4, 5, 6, 8, 10 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5,

Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.

For pipe thread type N, an NPT thread conversion fitting set is included. 19 Not included for Option Z (Removed parts) 20 Not included for Options Z and Z1 (Removed parts) 15 Thermo-chiller/Rack Mount Type HRR Series Specifications: 200 to 230 VAC Water-cooled Refrigeration Model HRR012-W-20 HRR018-W-20 HRR024-W-20 HRR030-W-20 Cooling method Water-cooled refrigeration Refrigerant R410A

Filter Rc3/8 20 m V V 5 Flow meter Rc1 V Prepare a flow meter with an appropriate flow range.

Power supply output VI: 20 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 20 [kVA] x 0.85 = 17 [kW] Cooling capacity = Considering a safety factor of 20%, 17 [kW] x 1.2 = W Efficiency Q = P = In this example, using an efficiency of 0.7: 13 0.7 = = 18.6 [kW] Cooling capacity = Considering a safety factor of 20%, 18.6 [kW] x 1.2 = 22.3 [kW] 20.4 [kW] *1

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, LEFT SIDE PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

-AN-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 4.80000 lb