SMC Corporation of America
Elite Part Number Search
Search Results "HRS012-AN-10-JMT"

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: -

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BASE FOR HRS024-AN-20-JMT-X021, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values. 

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, LEFT SIDE PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

-AN-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 4.80000 lb

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, UPPER PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJT (B + J + T)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BT ( B + T)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BM (B + M)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BW (B + W)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Earth Leakage Breaker