31 Auto switch mount bracket BJ 31 11.
Size: 10 to 50 B A Magnet Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch Lm Reed auto switch Solid state auto switch Hysteresis angle DM9 DA9, DA9V Size Rotating angle Operating angle m 10 10 10 10 Operating angle m 10 10 10 10 B 45 62 68 83 B 49 66 72 87 A 27 35 39 49 A 31 39 43 53 Hysteresis angle 90 80 65 50 42 35 30 24
-AN-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
ZK2-OM01301 Manifold ZZK2 04 A A 1 L 00 00 (1) (2) (3) (4) (5) (6) Remains blank when no option is selected. (1) Number of stations Note 1) Symbol Stations 01 1 station 02 2 stations 10 10 stations Note 1) In the case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.
ZK2-OM00201 Manifold ZZK2 04 A 1 L 00 00 (1) (2) (3) (4) (5) (6) Remains blank when no potion is selected. (1) Number of stations Note 1) Symbol Stations 01 1 station 02 2 stations 10 10 stations Note 1) In the case of an ejector, for an adequate performance, the number of stations when operated simultaneously depends on the nozzle diameter.
to 24 VDC 10%, Ripple (P-P) 10% or less 15 mA or less 2% F.S.
an odd number, an even number that is one larger than this odd number is used for the calculation. 75 100 + 100 (n 2) (n = 2, 3, 4, 5) D-G39/K39 D-A3/A44 35 + 30 (n 2) (n = 2, 3, 4, 5) 10 35 100 Note 1) Auto switch mounting Auto switches 2 pcs.
10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type weight of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C).
Switch bracket Auto switch b Switch holder d Auto switch mounting screw c Auto switch mounting band D-X Technical Data 375 CG3 Series Operating Range (mm) Auto switch model Bore size 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-M9A(V) 4.5 5.0 4.5 5.5 5.0 5.5 D-A9 7 6 8 8 8 9 D-C7/C80 D-C73C/C80C D-B5/B64 D-B59W D-H7/H7W D-H7NF/H7BA 9 8 10 10 10 11 8 10 9 10 10 11 11 11 13 13 14 14 14
Zone 40 :/ 1 30 " /' i 20 ;/ Danger Zone 10 SOOO 1
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
OUT PIPE ASSY, HRS012~024-A-10/20, CHILLER, 729, 200 lb
~024-A/W-10/20, CHILLER, 729, 100 lb
An optional remote adiustment cable provides adiustment control in otherwise inaccessible locations.
With individual release pressure supply (PD) port type Note 21) D PD port Note 19) When more than one option is selected, list the option symbols in an alphabetical order. Example) -BJ Note 20) For an ejector, PE is common with EXH, so it is not necessary to specify the option. Thread size is M3. Note 21) Only M3 is available for PD port size.
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: -
._ I 10, 22o, 12, 24, 48' 24ov sodoHz DC -24,6,12, 48, 100, 1 10v Voltag6 allowance 15.' + 10% of rated voltage lrcUlailon-Class B or equivalent Power consumptim AC Inrush-5.6VA(soHz)' 5.0VA(6OHZ) Hotdino-3.4VA(5OHz), 2.3VA(6OHz) DC_ 1.8W/2W (With LED) Indicator light Surg voltage supp(Gsor circuil AC ZNR (Varistor) ,Neon lamp (LED 10OV or le6s) DCDiode.
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: BJ (B + J)