Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: BJMW
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: M [Applicable to DI Water (Deionized Water) Piping]
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: BJMW
+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW t e q IN OUT t e q r IN OUT w r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
Then, the charging time (T) for a 100l tank, V 10 T = t x = 110 x = 110(s). 10 10 T = t x = 49 x = 49(s). 10 10 V 10 T = t x = 12.4 x = 24(s). 100 10 V 10 1.13-2 VBA1110 to 4200 Size Selection Pulsation is decreased by using tank. If secondary capacity is undersized, pulsation may occur.
AC AF + AR + AL AW + AL AF + AR AF + AFM + AR AW + AFM Attachments AF AFM / AFD AR AL AW wClean Series For details, refer to the Clean Series/Low Particle Generation section of the Web Catalog. 10 Standard model no.
40C M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 AW + [S] + AFM AC20D to 40D AC10: M5 x 0.8 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC50: 3/8 AC55: 1/2 AC60: 1/2 AC10 to 60 AF + [T] + AR + AL T T-interface AC10B to 60B AF + [T] + AR AC20C to 40C AF + AFM + [T] + AR AC20 to 50 AF + AR + AL + [V] AC20A to 40A AW + AL + [V] Residual pressure relief 3 port valve V AC20B to 50B AF + AR + [V]
40C M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 AW + [S] + AFM AC20D to 40D AC10: M5 x 0.8 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC50: 3/8 AC55: 1/2 AC60: 1/2 AC10 to 60 AF + [T] + AR + AL T T-interface AC10B to 60B AF + [T] + AR AC20C to 40C AF + AFM + [T] + AR AC20 to 50 AF + AR + AL + [V] AC20A to 40A AW + AL + [V] Residual pressure relief 3 port valve V AC20B to 50B AF + AR + [V]
Applicable bore size TC TDH10 TH TK TN TT TU TV TW TX TY TZ CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 CJ-T010C 10 4.5 3.3+0.048 0 29 18 3.1 2 9 40 22 32 12 8 CJ-CF016 CJ-CR016 16 10 12 15 M5 x 0.8 7 12 10 CJ-T016C 16 5.5 5+0.048 0 35 20 6.4 2.3 14 48 28 38 16 10 * A T-bracket includes a T-bracket base, single knuckle joint, hexagon socket head bolt and spring washer. * For dimensions of
AC10 AC20 AC25 AC30 AC40 AC50 AC55 AC60 : M5 x 0.8 : 1/8 : 1/4 : 1/4 : 3/8 : 3/8 : 1/2 : 1/2 AC10 to 60 AF + [T] + AR + AL T T-interface AC10B to 60B AF + [T] + AR AC20C to 40C AF + AFM + [T] + AR AC20 to 50 AF + AR + AL + [V] AC20A to 40A AW + AL + [V] 3-port valve for V residual pressure AC20B to 50B AF + AR + [V] release AC20C to 40C AF + AFM + AR + [V] Accessories AC20D to 40D AW + AFM
Note 2) Drain guide: G1/4 (applicable to AC25 to 60) AW + [S] + AFM AC20D to 40D AC10: M5 x 0.8 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC50: 3/8 AC55: 1/2 AC60: 1/2 AC10 to 60 AF + [T] + AR + AL T T-interface AC10B to 60B AF + [T] + AR Port size M5 01 02 03 04 06 10 M5 x 0.8 1/8 1/4 3/8 1/2 3/4 1 AC20C to 40C AF + AFM + [T] + AR AC20 to 40 AF + AR + AL + [V] AC20A to 40A AW + AL + [V] 3-
+ AFM AC20D to 40D AC10: M5 x 0.8 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC50: 3/8 AC55: 1/2 AC60: 1/2 AC10 to 60 AF + [T] + AR + AL T T-interface AC10B to 60B AF + [T] + AR AC20C to 40C AF + AFM + [T] + AR AC20 to 50 AF + AR + AL + [V] AC20A to 40A AW + AL + [V] 3-port valve for V residual pressure AC20B to 50B AF + AR + [V] release AC20C to 40C AF + AFM + AR + [V] Accessories AC20D to
Drip failure can cause damage to the components that need lubrication. 510 Lubricator Series AL10 to AL60 Construction AL10 AL20 w w q AC-A e q t AF-A OUT IN OUT IN AF-A y r u y u AR-A AL-A AW-A AC AL30, AL40 AL50, AL60 AF w q t e w q t e AF AR IN OUT IN OUT AL AL y r u r i AW AG E AV y AF u Component Parts No.
www.stevenengineering.com I 6.12 VACUUM VACUUM PADS SERIES ZP H O W T O O R D E R ZPT P A D V E R T I C A L T Y P E W I T H B U F F E R ZPT N P A D D I A M E T E R M O U N T I N G T H R E A D 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 Symbol Thread dia. 2~8 10~32 40~50 A8 M8X1 Male thread A10 M10X1 A14 M14X1 V A C U U M E N T R Y Symbol Port size 2~8 10~32 40~50
+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW t e q IN OUT t e q r IN OUT w r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
Refer to pages 12-10-4 to 12-10-5 for the details on effective holding force and allowable overhanging distance. Misc. D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !
M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13