Model Section Type Round type Standard G27-10-R1 G36-10-l01 G46-10-l01 0.02 to 0.2 MPa setting G27-10-R1 Note 2) G36-4-l01 G46-4-l01 Round type (with color zone) Standard G36-10-l01-L G46-10-l01-L 0.02 to 0.2 MPa setting G36-4-l01-L G46-4-l01-L Pressure gauge Note 1) Option Spacer Y100-A Y200-A Y300-A Y400-A Y500-A Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A AC-A Check valve

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15

Applicable model HRR012/018--10-T/MT*1 HRR012/018/024/030--20-T HRR012/018/024/030--20-MT1 Pump Rated flow (50/60 Hz)2, 3 L/min 7 (0.36 MPa)/10 (0.42 MPa) 10 (0.42 MPa)/14 (0.40 MPa) 10 (0.32 MPa)/14 (0.32 MPa) Maximum pump head (50/60 Hz) m 50 50 50 Output W 350 550 Circuit protector A 15 15 (10 A for standard) Recommended earth leakage breaker capacity A 15 Cooling capacity4 W The cooling

air outlet 40 or less 330 10 954 715 1538 A 1026 4 x 12 984 627 677 Anchor bolt mounting position (View A) For piping port sizes, refer to the Parts Description on page 5. 2 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Dimensions HRL200-A-40 Ventilation air inlet Ventilation air inlet Ventilation air outlet 715 40 or less 954 330 10 1538 A 1026 984 4 x 12 627 677 Anchor

Existing model 15 10 Heating functions are required to maintain a constant temperature particularly in the winter when the ambient temperature is low. 5 0 0 5 10 15 Time [Minute] Anti-freezing function is also available!

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

A large digital display provides a clear view of the current and set values.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS012-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?

A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?

A large digital display provides a clear view of the current and set values. 

As a guide, it should be replaced after 6000 to 8000 hours of operation.
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company.


For the HRS012 to 060 and the HRSE series, alarm code “AL29” (fan motor maintenance) will be activated every 20,000 hours of operation (Note 1). Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.

A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?