Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option: Conforming to UL Standards
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: T1+U)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: T1+U)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: T1+U)
Cooling Capacity: 012 [1000/1200, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: Inverter Pump Mounted, Option 2: -
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: Water-cooled, Pipe Thread: Rc, Option 1: Inverter Pump Mounted, Option 2: -
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)]
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: -
Cooling Capacity: -, Cooling Method: -, Pipe Thread: -, Option 1: -, Option 2: -
THERMO CHILLER, CHILLER, 729, 40 lb
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: Rc, DI Water Piping: None, High Pressure Pump: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 050 [5500/5900 W (50/60 Hz)], Pipe Thread: Rc, DI Water Piping: None, High Pressure Pump: Inverter Pump Mounted, Feet: -, Flow Sensor: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option 1: Inverter Pump Mounted, Option 2: -
Rack Mount Refrigeration Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 41.00000 lb
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: MT1 (M+T1), Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: TU (T+U)