Coolant temperature stability is ±0.1°C within a set temperature range of 5 to 35°C (15 to 35°C for HRR010). This device is self-contained with coolant and refrigerant circuits, fan cooled heat exchanger, electronic controls, pump, tank and power supply.
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DMT1 (DM + T1)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T1 (Inverter Pump Mounted)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: MT1 (M + T1)
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM + T1, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Inverter Pump Mounted, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: w/Feet, w/o Rack Mounting Brackets
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 010 [770/950 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: M + T1, Option 2: -
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: T1U (T1+U))
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: U (Conforming to UL Standards)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: DMU (DM+U)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: MT1U (M+T1+U)
Cooling Capacity: 010 [950/1100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: T1U (T1+U))
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DMT1 (D+M+T1)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)