Solid State Relay for HEC006/HEC012, THERMO CONTROLLER, PELTIER TYPE, 701, 200 lb
YES No Electric actuator PWR LED turns OFF Refer to Failure 1 ALM LED turns ON red Refer to Failure 2 Unable to communicate with electric actuator (JXC-W2A-C) Refer to Failure 3 The electric actuator does not operate correctly. Refer to Failure 4 Please contact SMC 57 - Problem Problem Investigation method and possible causes Countermeasures Possible No.
YES No Electric actuator PWR LED turns OFF Refer to Failure 1 ALM LED turns ON red Refer to Failure 2 Unable to communicate with electric actuator (JXC-W2A-C) Refer to Failure 3 The electric actuator does not operate correctly. Refer to Failure 4 Please contact SMC 62 - Problem Problem Investigation method No.
No5.Countor plug No6.Controller setting software 120.3 120.3 No1.Card Motor mm mm 200 200 Separately sold product mm/s mm/s No2.Actuator 100 500 100 500 1 1 200 1000 200 1000 2 2 cable 50 200 50 200 3 3 Prepared by the user No7.Controller setting cable Power Communication cable PC supply Power supply (LEC-W2A-C) (prepared by the cable 24 VDC user) USB cable (LEC-W2-U) for the
cable (1) How to Order L A T H 1 1 Cable length (L) 1 1m Note) There is direction for the actuator cable. 3 3m Connect the actuator side to the card motor. 5 5m There is a raised part on the controller side. (2) Dimensions Actuator side Controller side Protruding part 77 - 15.4 Controller setting cable (1) How to Order LECW2AC Communication cable LECW2U USB cable PC Communication cable (LEC-W2A-C
There is a raised part on the controller side. (2) Dimensions Actuator side Controller side Protruding part 86 - 15.4 Controller setting cable (1) How to Order L E C W 2 A C Communication cable L E C W 2 U USB cable PC Communication cable (LEC-W2A-C) USB cable (LEC-W2-U) Controller configuration software USB driver Download from SMCs website https://www.smcworld.com (2) Operating environment
Order an LEC-W2A-C communication cable and an LEC-W2-U USB cable.
Note) Connecting using a commercially available cable (LAN cable, etc.) may result in the malfunction of the product.
Cooling Capacity: 012 (1200W), Communication: A (RS-485)
Cooling Capacity: 1200W, Communication: RS-485, Option: -
Cooling Capacity: 006 (600W), Communication: A (RS-485)
Cooling Capacity: 006 (600W), Communication: B (RS-232C)
Cooling Capacity: 006 (600W), Communication: B (RS-232C)
Cooling Capacity: 600W, Communication: RS-232C, Option: -
Cooling Capacity: 600W, Communication: RS-485, Option: -
Cooling Capacity: 600W, Communication: RS-232C, Option: -
Cooling Capacity: 012 (1200W), Communication: A (RS-485), Option: N (NPT Thread)
Cooling Capacity: 1200W, Communication: RS-485, Option: NPT Thread
Cooling Capacity: 006 (600W), Communication: A (RS-485), Option: N (NPT Thread)
Cooling Capacity: 006 (600W), Communication: A (RS-485), Option: FN (w/Flow Switch, NPT Thread)
Cooling Capacity: 006 (600W), Communication: B (RS-232C), Option: F (w/Flow Switch)