SMC Corporation of America
Elite Part Number Search
Search Results "G46-2-01-SRA"

Optional specifications Model AR20(K)-D AR30(K)-D AR40(K)-D AR40(K)-06-D AR50(K)-D AR60(K)-D Bracket assembly*1 AR23P-270AS AR33P-270AS AR43P-270AS AR54P-270AS Set nut AR23P-260S AR33P-260S AR43P-260S *2 Round type Standard G36-10-m01 G46-10-m01 0.02 to 0.2 MPa setting G36-4-m01 G46-4-m01 Standard G36-10-m01-L G46-10-m01-L 0.02 to 0.2 MPa setting G36-4-m01-L G46-4-m01-L Round type (with color

Model Option AR20(K)-B AR25(K)-B AR30(K)-B AR40(K)-B AR40(K)-06-B AR50(K)-B AR60(K)-B Bracket assembly *1 AR23P-270AS AR28P-270AS AR33P-270AS AR43P-270AS AR52P-270AS Set nut AR23P-260S AR28P-260S AR33P-260S AR43P-260S *2 Round type *3 Standard G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G36-4-01 G46-4-01 Round type *3 (with color zone) Standard G36-10-01-L G46-10-01-L Pressure gauge 0.02

Refer to Specific Product Precautions on page 1006. 990 E-P HYREG VY1 Series R Standard Specifications 0 1 0 1 0 1 VY110 01 02 0 1 0 1 VY140 0 1 VY150 0 1 VY170 0 1 20 VY190 0 1 VY1D00 M5 VY1A0 VY1B0 M5 VY120 01 02 VY130 02 03 Model 10 12 10 04 02 03 04 04 06 14 M5 01 Port 1(P) 11 2 Port size 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 1 M5 M5 2 2 M5 2(A) 1 4 3(R) Weight

Model Option AR20(K)-B AR25(K)-B AR30(K)-B AR40(K)-B AR40(K)-06-B AR50(K)-B AR60(K)-B Bracket assembly Note 1) AR23P-270AS AR28P-270AS AR33P-270AS AR43P-270AS AR52P-270AS Set nut AR23P-260S AR28P-260S AR33P-260S AR43P-260S Note 2) Round type Note 3) Standard G36-10-01 G46-10-01 0.02 to 0.2 MPa setting G36-4-01 G46-4-01 (with color zone) Standard G36-10-01-L G46-10-01-L Pressure Round type

Regulator for 2 MPa ARX 20 How to Order ARX2 0 01 Regulator Options None Nil 1348112 G36 10 01 G46 10 02 G36 4 01 G46 4 02 G36 P10 N01 G46 P10 N02 G36 P4 N01 G46 P4 N02 1348110A B Regulating pressure range Bracket 0.05 to 0.85MPa 0.05 to 0.30MPa 0 1 ARX20 Nil F ARX21 Nil F Thread type G Pressure gauge Rc NPT G Nil N F ARX20N ARX21N P Port size Panel nut 1/8 1/4 01 02 Option

-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.

gauge AF-A Note 2) Round type (with color zone) Standard G36-10-l01-L G46-10-l01-L 0.02 to 0.2 MPa setting G36-4-l01-L G46-4-l01-L AR -A -B Note 1) Assembly of a bracket and set nuts Note 2) l in round pressure gauge part numbers indicates a pipe thread type.

Optional Parts ARP20(K) ARP30(K) ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G36-4-01 G46-4-02 Round type Note 2) 0.4 MPa Square embedded type Note 3) GC3-4AS [GC3P-010AS (Pressure gauge cover only)] G36-2-01 G46-2-02 Round type Note 2) 0.2 MPa Square embedded type Note 3) GC3-2AS [GC3P-010AS (Pressure gauge cover

Optional Parts ARP20(K) ARP30(K) ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G36-4-01 G46-4-02 Round type Note 2) 0.4 MPa Square embedded type Note 3) GC3-4AS [GC3P-010AS (Pressure gauge cover only)] G36-2-01 G46-2-02 Round type Note 2) 0.2 MPa Square embedded type Note 3) GC3-2AS [GC3P-010AS (Pressure gauge cover

0 Model VY1D00-M5 10 M5 01 M5 Port M5 01 02 01 02 02 03 20 04 02 03 04 04 06 10 12 14 P Port size Rc 11 2 1 1 8 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 4 3 8 1 2 1 2 3 4 1 1 1 4 A M5 M5 M5 2 1 4 R 2 1 0.11 0.16 Weight (kg) (1) 0.19 0.25 0.35 0.55 0.75 1.5 2 4 Hysteresis (2) 1% F.S. 2.5% F .S. 3% F .S. 5% F .S.

(mm ) 0 2 4 M V VX311 -01 1.5 ZCU 0.29 0 2 4 M V VX312 -01 2.2 1 8 0.60 AMJ 0 2 4 M V VX313 -01 3 0.82 Misc. 0 2 4 M V VX311 -02 1.5 0.29 0 2 4 M V VX312 -02 0.60 M V VX3224 -02 2.2 0.64 M V VX3324 -02 0 2 4 M V 0.82 VX313 -02 1 4 Series VX31 Series VX32 Series VX33 M V 3 VX3234 -02 1.1 M V VX3334 -02 M V 4 VX3244 -02 1.6 M V VX3344 -02 M V VX3224 -03 2.2 0.64 M V VX3324 -03 M V VX3234 -03

Proof pressure Max. operating pressure Set press. range Air operated Solenoid Ambient and fluid temperature Hysteresis Repeatability Sensitivity Mounting Lubrication Port 01 P A R mm2 02 01 02 03 04 04 06 10 10 12 14 20 02 Port size Rc(PT) 1 11 2 1 4 11 4 1 2 1 8 1 4 1 8 1 4 1 4 3 8 1 2 1 2 3 4 590 2 1 300 17 25 1.4 16 0.9 25 1.4 60 3.3 70 3.9 330 18 36 2.0 Cv 16 0.9 130 7.2 160 8.9 180 10

AR40P-270AS AR30P-270AS AR40P-270AS Set nut AR40P-260S AR30P-260S AR40P-260S G46-10-02 Round Square embedded type Round Square embedded type G46-10-02 G36-10-01 1.0MPa Note 3) GC3-10AS Note 2) GC3-10AS GC3-10AS 1 4 1 8 1 4 Note 1) Pressure gauge G46-2-02 G36-2-01 G46-2-02 Set pressure + 0.05MPa (at relief flow rate of 0.1l/min(ANR)) 5 to 60C (With no condensation) 5m 0.2MPa Note 3) GC3-2AS


・When mounting a pressure gauge with a non-standard pressure range on a VEX1 □3□ series regulator, keep in mind that the G36 and the G46 have a max. display pressure of either up to 0.2, up to 0.4, or up to 0.7 MPa.
The part numbers are as follows: G36(46)-2-01, G36(46)-4-01, G36(46)-7-01

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

)] PNP output / Wiring top entry Copper-free, Fluorine-free (20-) 20-ARP20(K) 20-ARP30(K) 20-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G46-4-l01-X3 G46-4-l02-X3 0.4 MPa Pressure gauge G46-2-l01-X3 G46-2-l02-X3 Round type Note 2) 0.2 MPa G46-7-l01-X3 G46-7-l02-X3 0.7 MPa Clean Room Compliant, Copper-free, Fluorine-free

ITV 2 1 Options IC Bracket ITVH Model B21-1-T1 Rolled steel plate (electroless nickel plated) Material ITVX Pressure gauge Product part no. SRP1-M5 SRP1-01 Pressure gauge part no.

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

G46-10-01) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter N. Please contact SMC concerning the supply of NPT pressure gauges. Relieving type is provided as standard for AU100.