This is a generic name for the Wireless Base and Remote units. -103No.EX##-OMV0017-D Revision history Revision Applicable models Updated content no. 2.00 EX600-WEN# EX600-WSV# First edition 2.10 EX600-WPN# EX600-WSV# Version for EX600-WPN# EX600-WEN# EX600-WPN# EX600-WSV# Common version for EX600-WEN# and EX600-WPN# ACS reader / writer has been added to verified NFC reader / writers. 2.20
AMB EX600-SDN, EX600-SDNA EX600-SPR, EX600-SPRA EX600-SMJ EX600-SEN EX600-SEC EX600-SPN SI unit (Occupies 8 outputs) SI (8SOL) EX600-SDN(A) EX600-SPR(A) EX600-SMJ EX600-SEN EX600-SEC EX600-SPN SI unit (Occupies 16 outputs) SI (16SOL) SI EX600-SDN(A) EX600-SPR(A) EX600-SMJ EX600-SEN EX600-SEC EX600-SPN SI unit (Occupies 24 outputs) SI (24SOL) EX600-SDN(A) EX600-SPR(A) EX600-SMJ EX600-SEN EX600
W.S. 032767 032767 +0+32767 3276865535 -0-32767 -0-32767 15 V()50001000 4 V PLC 4000 -57No.EX-OMS0026CN EX600 byte EX600 byte EX600 byte byte EX600-SEN3/4 (32 ) 0 4 SI EX600-SEN3/4 (32 ) 4 4 () EX600-DXB (8 ) 1 0 EX600-DXC (8 ) 1 0 EX600-DXC1 (8 ) 1 0 () EX600-DXD (16 ) 2 0 EX600-DXE (16 ) 2 0 EX600-DXF (16 ) 2 0 EX600-DYB (8 ) 0 1 EX600-DYE (16 ) 0 2 EX600-DYF (16 ) 0 2 EX600-DME
1 0 EX600-DXC (8 ) 1 0 EX600-DXC1 (8 ) () 1 0 EX600-DXD (16 ) 2 0 EX600-DXE (16 ) 2 0 EX600-DXF (16 ) 2 0 EX600-DYB (8 ) 0 1 EX600-DYE (16 ) 0 2 EX600-DYF (16 ) 0 1 EX600-DME (8/8 ) 1 1 EX600-DMF (8/8 ) 1 1 EX600-AXA 4 (2 byte/1 ) 0 (2 ) EX600-AYA (2 ) 0 4 (2 byte/1 ) EX600-AMB 4 4 (2/2 ) (2 byte/1 ) (2 byte/1 ) -65No.EX-OMQ0015CN EX600 SI [EX600-SPN# (32 coils, Status)]4 Byte No.
SI EX600 0 0 -9No.EX-OML0010CN-C EX600-HT1 EX600-HT1A EX600-SPR EX600-SPRA EX600-SDN EX600-SDNA SI EX600-SMJ EX600-SEN EX600-SEC EX600-SPN EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF (EX600-DYPE1) EX600-DME EX600-DMF (EX600-AXA) (EX600-AYA) (EX600-AMB) EX600-HT1 EX600-DEEX600-DFEX600-AYAEX600-AMB EX600-HT1A EX600-HT1A
Allocated bytes Unit Unit part number Input Output EX600-SEN3 / 4 (32 outputs) 0 4 SI unit EX600-SEN3 / 4 (32 outputs) (with diagnostic data) 4 4 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs) (with open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1 EX600-DYE (16 outputs
Occupied byte Unit Unit part number Input Output EX600-SEN (32 outputs) 0 4 EX600-SEN (24 outputs) 0 3 SI unit EX600-SEN (16 outputs) 0 2 EX600-SEN (8 outputs) 0 1 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs)(with open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1
Occupied byte Unit Unit part number Input Output EX600-SPN (32 outputs) 0 4 SI unit EX600-SPN (32 outputs diagnostic) 4 4 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) (with open circuit detection) 1 0 EX600-DXD Digital input unit (16 inputs) 2 0 EX600-DXE (16 inputs) 2 0 EX600-DXF (16 inputs) 2 0 EX600-DYB (8 outputs) 0 1 EX600-DYE (16 outputs) 0 2 Digital output unit EX600-DYF (16 outputs
Compatible Unit Notes 2.0.0 EX600-WEN EX600-WSV First edition 2.1.0 EX600-WPN EX600-WSV Version for EX600-WPN EX600-WEN EX600-WPN EX600-WSV Common version for EX600-WEN and EX600-WPN Advanced Card Systems Ltd. reader / writer has been added to verified NFC reader / writer. 2.2.0 EX600-WEN EX600-WPN EX600-WSV Added "Remote control" as a mode of setting IP address.
Compatible Unit Notes 2.00 EX600-WEN EX600-WSV First edition 2.10 EX600-WPN EX600-WSV Version for EX600-WPN EX600-WEN EX600-WPN EX600-WSV Common version for EX600-WEN and EX600-WPN Advanced Card Systems Ltd. reader / writer has been added to verified NFC reader / writer. 2.20 -122No.EX-OMV0017-B Revision history A: Contents revised in several places. [August 2018] B: Contents are added.
Compatible Unit Notes 2.00 EX600-WEN EX600-WSV First edition 2.10 EX600-WPN EX600-WSV Version for EX600-WPN EX600-WEN EX600-WPN EX600-WSV Common version for EX600-WEN and EX600-WPN Advanced Card Systems Ltd. reader / writer has been added to verified NFC reader / writer. 2.20 -122No.EX-OMV0017-A Revision history A: Contents revised in several places.
SI Unit EX600-SPRA EX600-SPR (PROFIBUS DP) (PROFIBUS DP) EX600-SMJ EX600-SEN (CC-Link) (EtherNet/IP) EX600-SDNA EX600-SDN (DeviceNet) (DeviceNet) EX600-DXB EX600-DXC EX600-DXD EX600-DXE Digital unit EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA Analog unit EX600-AYA EX600-AMB EX600-HT1 H.T. EX600-HT1A H.T.
-SPR EX600-SPRA (PROFIBUS DP) (PROFIBUS DP) EX600-SMJ EX600-SEN (CC-Link) (EtherNet/IP) EX600-SDN (DeviceNet) EX600-SDNA (DeviceNet) EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA EX600-AYA EX600-AMB H.T.
Occupied word size Unit Unit part number Input Output System diagnostic 1 0 Diagnostic data Unit diagnostic 1 0 SI unit EX600-SPL1-X26 (32 outputs) 0 2 EX600-DXB (8 inputs) 1 0 EX600-DXC (8 inputs) 1 0 EX600-DXC1 (8 inputs) (with open circuit detection) 1 0 Digital input unit EX600-DXD (16 inputs) 1 0 EX600-DXE (16 inputs) 1 0 EX600-DXF (16 inputs) 1 0 EX600-DYB (8 outputs) 0 1 EX600-DYE
For an EX600-SPN3/4 SI unit: SMC-EX600-SPN-LxB1-202*-IOLM1.5.zip For an EX600-SPN3/4 SI unit: SMC-EX600-SEN7_8-LxB1-202*-IOLM1.5.zip For an EX600-SPN3/4 SI unit: SMC-EX600-SEC3_4-LxB1-202*-IOLM1.5.zip For an EX600-SEN3-X80 SI unit: SMC-EX600-SEN-LxB1-202*-IOLM1.5.zip For an EX245-SPN1A SI unit: SMC-EX245-SPN_FX-Lx1-202*-IOLM1.5zip For an EX245-SPN2A/3A SI unit: SMC-EX245-SPN_Cu-Lx1-202*-IOLM1.5zip
-byte output 2-byte output 2-byte output Wireless master module construction Input data: [Unit 1] Digital input unit (EX600-DX#D): 2 bytes occupied Output data: [Unit 0] Digital output unit (EX600-DY#B): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DY#B AXA DX#D EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001
EX600-LAB1 EX600-LBB1 Common for IO-Link port No. 1, 2, 3 and 4 (C/Q: Pin No.4) of EX600-LAB1 and EX600-LBB1 The LED status varies depending on the setting of Pin No.4 (disabled, IO-Link communication, digital I/O) of ports No. 1 to 4.
Auto switch M12 M12 M12 M12 x 2 K #6 K #4 EX600-DX B, DX D M8 M8/M12 connector (Field-wireable/Pre-wired) EX600-DX C, DX C1 M12 M8 x 2 K #7 K #4 Only the M12 type connector is available for the 2-input type input block. Pre-wired type P Product Table Description Application No. SMC part no.
Analog output unit EX600-AYA 1 4 6 5 DIN rail mounting groove 4 Analogl I/O unit EX600-AMB Valve plate mounting groove 1 Intermediate reinforcing brace (EX600-ZMB2) Intermediate reinforcing brace (EX600-ZMB1) 1 2 6 DIN rail 2 Valve plate (EX600-ZMV ) 1 End plate bracket (EX600-ZMA2) 5 2 5 3 3 4 Configuration Examples of wiring with input devices When using a sensor whose analog output signal
Installation Base 1 Direct mounting (1) When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4 x 5 screws. Tightening torque: 0.7 to 0.8 Nm 2 4 5 10 Thank you for purchasing an SMC EX600-WEN#/EX600-WSV# SMC Wireless System.