Note 2) Add -61 at the end of the part number for the flexible lead wire. (Example) When ordering with an air gripper 61 MHZ 2-16D-F8NSFlexible lead wire When ordering auto switches only 61 D-F8PLFlexible lead wire Note 3) Through-hole mounting is not possible when using auto switch types D-Y59, D-Y69, or D-Y7.

SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.

Without light SY100-61-1 With light Rated voltage Rating symbol 24V 12V 100V 200V 110V 220V Part No. SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution 24VDC 12VDC 100VAC 200VAC 110VAC 220VAC How to Use the DIN Terminal Connector (SY5000/7000 only) Connection 1.

D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C Yes/2 Wire Yes/2 Wire 20mA 4~8VDC 50mA 40mA 20mA 24V 48V 110V No/2 Wire ACCESSORIES SWITCH BANDS FOR

(When using 10-SS5Y-60-D, block disk is assembled on D side.) sheet. (When using 10-SS5Y-60-D, block disk is assembled on D side.)

/location) c Individual SUP spacer assembly Options d Individual EXH spacer assembly Notes: Blanking plate assembly: SY9000-26-3A SUP block disc: SY9000-61-2A EXH block disc: SY9000-61-2A (2 pcs.

219 124 150 2 265 J D-X 20Data 10-2-61 61 Series REAH Proper Auto Switch Mounting Position (Detection at stroke end) Piping port surface A B Proper Auto Switch Mounting Position (mm) A dimension B dimension Auto switch model D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Z7 D-Z80 D-Z7 D-Z80 D-Y7W D-Y7WV Cylinder model REAH10 65.5 65.5 65.5 59.5 59.5 59.5 REAH15 72 72 72 122

SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.

(Including bracket, screw) Applicable bore size (mm) 40 BMU2-040 50 BMU2-040 63 BMU2-040 Cylinder series MDU 8-30-60 61 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Tie-rod Mounting Style Reed switchD-A53, D-A54, D-A56, D-A64 D-A67, D-A59W Solid state switchD-F59, D-F5P D-J59, D-J51, D-F5BAL D-F59W, D-F5PW, D-J59W D-F59F, D-F5NTL

D-M9(V)/M9W(V)/M9A(V) D-A9(V) D-B5/B6 D-G5/K5 Hs Hs B A B A D-B7/B8 D-G7/K7 D-C7/C8 D-H7 Hs Hs B A B A Proper Auto Switch Mounting Position (mm) Proper Auto Switch Mounting Height (mm) D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C D-H7C D-G5NT D-G5/K59 D-G5W D-K59W D-B5/B64 D-B59W D-G5BA D-G59F Auto switch model D-G59F/G5 D-K59 D-G5W D-K59W D-G5NT D-G5BA Auto switch model D-H7 D-H7C D-H7NF D-H7W

D-M9BW L (Example) D-F7PLLead wire length 61 0.5 m 1 m 3 m 5 m None Nil M L Z N Flexible specification (D-Y59, D-Y69, D-Y7 and D-M9 series use flexible lead wire as standard. ) Applicable for the connector type (DC) only.

Applicable Cylinder Series: CDBQ2 (With end lock) (mm) Auto switch model D-A7lH D-A80H/J79W D-F7l/F7BAL D-J79/F79F D-F7lW/F7NTL D-F7lV D-F7lWV D-F7BAVL D-J79C D-A79W D-A9lV D-M9lV D-M9lWV D-M9lAVL D-A7l D-A80 D-A73C D-A80C D-P4DWL Bore size U 38.5 42 48 54.5 64.5 74.5 U 44 50 56.5 66.5 76.5 U 31.5 35 41 47.5 57.5 67.5 U 32.5 36 42 48.5 58.5 68.5 U 35 38.5 44.5 51 61 71 U 38 41.5

Without light SY100-61-1 With light Model no. SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Voltage symbol 24 V 12 V 100 V 200 V 110 V 220 V Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC How to Use DIN Terminal Caution Connection 1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block. 2.

Reed auto switch: D-A9, D-A9V Solid state auto switch: D-M9(A), D-M9W D-M9 Compact auto switch D-A9 5 Air Slide Table MXQ Series Functional Options ' With buffer mechanism Protects workpieces and tools by eliminating impact at the extension stroke end Buffer unit is auto switch capable.

D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C Yes/2 Wire Yes/2 Wire 20mA 4~8VDC 50mA 40mA 20mA 24V 48V 110V No/2 Wire ACCESSORIES SWITCH BANDS FOR

ZP3EU-YF4JB10 [Weight: 430 g] ZP3EU-YF4JB30 [Weight: 461 g] ZP3EU-YF4JB50 [Weight: 486 g] Width across flats 17 Width across flats 30 Width across flats 17 Width across flats 30 Bushing Bushing 50 8 8 8 8 50 A B Bushing Bushing M22 x 1.5 M22 x 1.5 B A D-D D-D Rc1/8 Rc1/8 22 22 D D D D 26 26 32 32 11 11 42 42 19 19 4 4 11.11) 11.11) 30 (Rotating angle) 30 (Rotating angle) 50 61 Dimensions

AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12 1 Large Flow Air Filter Series AF800/900 Standard Specifications F.R.L.

Add -61 at th end of the part number for the flexible lead wire except D-Y59, D-Y69, DY7 and D-M9/M9V type auto switches. L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.