SMC Corporation of America
Elite Part Number Search
Search Results "D-H7CN"

Auto Switch Mounting Height (mm) Auto Switch model D-B5 D-B64 D-B59W D-G5NTL D-H7C D-C7 D-C80 D-H7 D-H7W D-H7NF D-H7BAL D-G39 D-K39 D-A33 D-A34 D-A9 D-M9 D-M9W D-C73C D-C80C D-A44 Bore size (mm) Hs Hs Hs Hs Hs Hs 20 24.5 27 62 72 24 27.5 25 27 29.5 64.5 74.5 26.5 30 32 30.5 33 68 78 30 33.5 40 35 37.5 72.5 82.5 34.5 38 REA REB REC CY CX MQ RHC RZQ D-X Individual -X 1039 Series REC Operating

. 6.8 to 11.5) D-C73C/C80C D-H7C Auto switch Hs Auto switch Hs B A B A 13 Series CM3 Auto Switch Proper Mounting Position (Detection at stroke end) and Its Mounting Height Auto Switch Proper Mounting Position (mm) Auto switch model D-A3lA D-A44A D-G39A Note 2) D-K39A Note 2) D-M9l D-M9lW D-A9l D-B59W D-H7C D-H7BAL D-H7NF D-G5NTL D-B54 D-B64 D-C73C D-C80C A A B A B B B A B A B A B A B Bore

You do not need to specify "N" (i.e., without lead wire) for D-A3, D-A44, D-G39, and D-K39. This is the only standard specification automatically available for these models. D-A9V, M9V, M9WV, and M9A(V) models cannot be mounted on 25 to 40. Since there are applicable auto switches other than listed, refer to page 310 for details.

(For band mounting, only the auto switch mounting brackets are assembled before shipment.) * When mounting a band on bore size 8, 10, or 12, the D-A9l(V) cannot be mounted. * When mounting a rail on bore size 8, 10, or 12, the D-A9l(V) and A79W cannot be mounted. * When mounting a rail on bore size 20 or 25, the D-M9l(V), M9lW(V), and M9lA(V) cannot be mounted. 2 C85 Series Specications Bore

Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked "" are produced upon receipt of order. Do not indicate lead wire length symbol N (none) for types D-A3, D-A44, D-G-39 or D-K39.

Rod end thread Male thread Female thread Long male rod end Nil F G Cushion CG1 Mounting Auto switch mounting bracket Note) N Rubber bumper B L F G D Basic Foot Rod flange Head flange Clevis Note) This symbol is indicated when the D-A9 or M9 type auto switch is specified. This mounting bracket does not apply to other auto switches (D-C7 and H7, etc.)

Band mounting style is not available for D-A9V/M9V/M9WV and D-M9A(V)L types. D-A79W cannot be mounted on bore size 10 cylinder with air cushion. Lead wire length symbols: 0.5 m 1 m 3 m 5 m None Solid state auto switches marked with are produced upon receipt of order. D-A9/M9/M9W/A7/A80/F7/J7 auto switches are shipped together (not assembled).

Please consult with SMC regarding water resistant types with the above model numbers. *2 1 m type lead wire is only applicable to D-A93. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN D* Since there are other applicable auto switches than listed above, refer to page 154 for details. * For details

Do not indicate suffix N for no lead wire on the D-A3lA/A44A/G39A/K39A types. The D-G39A/K39A cannot be mounted on the bore size 20. The D-A9lV/M9lV/M9lWV types and the D-M9lA(V)L type cannot be mounted. Since there are other applicable auto switches than listed above, refer to Best Pneumatics.

D-A9/M9/M9W auto switches are shipped together (not assembled). (However, auto switch mounting brackets are assembled when being shipped.) Solid state auto switches marked with are produced upon receipt of order. D-A9V/M9V/M9WV and D-M9A(V)L cannot be mounted. Do not indicate suffix N for no lead wire on D-A3A/A44A/G39A/K39A models.

D-A9V/M9V/M9WV/M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) H7CN Since there are other applicable auto switches than listed, refer to page 1040 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.

D-A9V/M9V/M9WV/D-M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.

D-B54, B64, and B59W cannot be mounted for bore size 044 and 056. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN For details about auto switches with pre-wired connector, refer to Best Pneumatics catalog. D-A9, M9, M9W are shipped together.

D-A9V/M9V/M9WV/M9A(V) types cannot be mounted. Caution Since there are other applicable auto switches than listed, refer to page 406 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W auto switches are shipped together (not assembled). (Only switch mounting brackets are assembled at the time of shipment.)

D-A9V/M9V/M9WV/M9A(V) types cannot be mounted. Caution Since there are other applicable auto switches than listed, refer to page 388 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W auto switches are shipped together (not assembled). (Only switch mounting brackets are assembled at the time of shipment.)

Magnet: Built-in, Mounting: Front Block, Bore Size: 1 1/2", Stroke: 1", Cushion: w/o Rubber Bumper, Auto Switch: H7C--Solid State, Gen. Purpose, 2 Wire, Connector, Lead Wire or Prewired Connector: No Lead Wire, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Bore Size: 40mm, Port Thread: Screw-in Piping, Stroke: 30mm, Action: Single Acting/Spring Extend, Rod End Configuration: Lever Style (Adjustment-free), Basic Style), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: No Lead Wire, Number: -, Auto Switch Mounting Bracket: -

Magnet: Built-in, Bore Size: 40mm, Port Thread: Built-in One-touch Fitting, Stroke: 30mm, Action: Single Acting/Spring Extend, Rod End Configuration: Lever Style (Adjustment-free), Basic Style), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: No Lead Wire, Number: -, Auto Switch Mounting Bracket: -