75 133 368 Up to 1000 98 345 345 388.5 452 477 368 368 409.5 470 495 8 9 0.2 stroke 98 345 30 to 1000 75 133 368 98 Up to 1000 0.2 stroke 106 388.5 75 141 409.5 106 30 to 1200 Up to 1200 0.2 stroke 111 448 85 153 466 115 30 to 1200 Up to 1200 0.2 stroke 111 468 90 153 486 120 30 to 1200 Up to 998 0.2 stroke 141 579.5 105 176 595.5 30 to 1200 0.17 stroke 9-9-12 13 Series CLS Cylinder with

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

Operating pressure: 1 MPa Lateral load 1000 Stroke 100 Eccentric distance 100 80 Load weight (kg) 1000 63 10 50 40 32 25 20 1.0 100 Allowable lateral load (N) 0.1 10 100 1000 Maximum piston speed (mm/s) 100 80 63 50 40 10 32 25 20 1 0 50 100 150 200 Stroke + Eccentric distance (mm) Refer to Model Selection in Best Pneumatics No.2 for details about model selection procedure. 3 ISO Standards

Mr = 1 x 9.8 (30 + 10.5)/1000 = 0.39 A = 10.5 Examine My. My = 1 x 9.8 (10 + 30)/1000 = 0.39 A3 = 30 Find the static moment M (Nm). M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table 3 Find the allowable static moment Ma (Nm).

My = 0.5 x 9.8 (10 + 11)/1000 = 0.11 A3 = 11 May = 1 x 1 x 9.14 = 9.14 Mymax = 9.14 K = 1 = 1 2 = 0.11/9.14 = 0.012 Examine Mr.

Examine for Mep (20+6.8) Mep=1/333.6 =0.3 1000 We=42420/100=33.6 A2=6.8 Meap=0.71.7=1.19 =0.7 Mp max.=1.7 3=0.3/1.19=0.252 (Ln+An) Me=1/3We 1000 Load equivalent to collision We=4WV/100 Corrected value for center position distance of moment An : Table 3 Calculate allowable kinetic moment Mea(Nm). Mea=M max.

Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston

(between lead wire and case) 1000 VAC for 1 min.

V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

V(mm/s) = x 1000 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life.

V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

Lead wire length 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid

A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L