Mr = 1 x 9.8 (30 + 10.5)/1000 = 0.39 A = 10.5 Examine My. My = 1 x 9.8 (10 + 30)/1000 = 0.39 A3 = 30 Find the static moment M (Nm). M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table 3 Find the allowable static moment Ma (Nm).

My = 0.5 x 9.8 (10 + 11)/1000 = 0.11 A3 = 11 May = 1 x 1 x 9.14 = 9.14 Mymax = 9.14 K = 1 = 1 2 = 0.11/9.14 = 0.012 Examine Mr.

Examine for Mep (20+6.8) Mep=1/333.6 =0.3 1000 We=42420/100=33.6 A2=6.8 Meap=0.71.7=1.19 =0.7 Mp max.=1.7 3=0.3/1.19=0.252 (Ln+An) Me=1/3We 1000 Load equivalent to collision We=4WV/100 Corrected value for center position distance of moment An : Table 3 Calculate allowable kinetic moment Mea(Nm). Mea=M max.

Lateral load Operating pressure: 1 MPa 1000 200 300 500 Stroke Eccentric distance 100 100 Load weight (kg) 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 63 Allowable lateral load (N) 50 40 63 1 32 25 20 50 40 10 32 0.1 25 10 100 200 300 500 1000 Maximum piston

(between lead wire and case) 1000 VAC for 1 min.

V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

V(mm/s) = x 1000 4. Keep wiring as short as possible. As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the products life.

V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.

Lead wire length 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid

A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L

Piping: Standard, Bore Size: 25mm, Port Thread: NPT, Stroke: 1000mm, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Piping: Standard, Bore Size: 25mm, Port Thread: TN (NPT), Stroke: 350mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: Standard, Bore Size: 25mm, Port Thread: TN (NPT), Stroke: 400mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: Standard, Bore Size: 25mm, Port Thread: TN (NPT), Stroke: 200mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Piping: Standard, Bore Size: 25mm, Port Thread: NPT, Stroke: 350mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -