Applicable models: D-A93, D-Z73
Note 2) ( ): Denotes the dimensions of D-Z73. Since this is a guideline including hysteresis, not meant to be guaranteed. (assuming approximately 30% dispersion.) There may be the case it will vary substantially depending on an ambient environment.
Applicable models: D-Z73
/Z76/Z80 Auto Switch Specifications With indicator light D-Z73 D-Z76 Auto switch part no.
/Z76/Z80 Auto Switch Specifications With indicator light D-Z73 D-Z76 Auto switch part no.
Applicable models: D-Z73
D L RSH RS1H 30 50 Z73 D L Bore size Number of auto switches 50mm 63mm 80mm 50 63 80 Thread type Nil S 2 pcs. 1 pc.
Note 1) Lead wire length: Z (5m) applicable auto switches Reed: D-B53, D-B54, D-C73(C), D-C80C, D-A53, D-A54, D-A73(C)(H), D-A80C, D-Z73 Solid state: All types are produced upon receipt of order.
AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Pre-wire connector Wiring (Output) Special function Type Electrical entry Applicable load 3 (L) 5 (Z) 0.5 (Nil) Perpendicular In-line 3-wire IC circuit Z76 5 V Reed switch Solid state switch Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC Y69A Y7PV
Specifications Notes) Lead wire length Z (5m) applicable auto switches Reed switch: D-Z73 Solid state switch: All types are produced upon receipt of order. Part no. CD-P12 CD-P11 100VAC Load voltage 200VAC 24VDC For D-Y5, D-Y6, and D-Y7, flexible wire specification is standard.
Lead wire length indication Note 1) Applicable auto switch with 5 m lead wire (Z) Reed switch: D-B53/B54, D C 7 3 ( C ) / C 8 0 C , D A 7 3 ( C ) ( H ) / A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard.
D-J51: 5ms or less MHZ2 Lead Wire Length MHZJ2 How to specify lead wire length MHQ (Example) MHL2 L D-A73 MHR Lead wire length 0.5m 3m L 5m Z N MHK MHS None Applicable to only connector type switch D-C MHC2 Note 1) Lead wire length Z: 5m Applicable to Reed switch: D-B53/B54, D-C73 (C)/C80C, D-A73 (C) (H)/A80C MHT2 Solid state switch: Made to order (Except D-F9, F9lV, F7lWV) D-A53/A54, D-Z73
Lead wire length (m) Load voltage Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39 G59W G5PW K59W G5BA G59F Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C
Lead wire length (m) Load voltage Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC 3-wire (NPN equivalent) Z76 5 V IC circuit Grommet B53 B54 A33 A34 A44 B59W G59 G5P K59 G39 K39 G59W G5PW K59W G5BA G59F Z73 A54 A33C A34C A44C A59W Y59A Y7P J51 Y59B G39C
Series IDG30A to 100A Flexible mounting orientation Series IDG1 Space saving Max. 59 mm Easy to install in narrow spaces!
Piping Power consumption Faston terminal type added Enclosure Flange type, Flange body type added Port size 50A to 100A added 4.5 W IP65 Electrical entry Faston type terminal is IP40. Excluding size 23 Flange type Flange body type Mounting can be changed depending on the piping conditions. Orifice machining on the outlet is not necessary, so piping man hour is reduced!
type Output 24VDC relay, PLC Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24VDC (4.5 to 28VDC) Current consumption 10mA or less 28VDC or less 24VDC (10 to 28VDC) Load voltage 80mA or less 40mA or less 5 to 40mA Load current 1.5V or less 0.8V or less 4V or less Internal voltage drop (0.8V or less at a load current of 10mA) 0.8mA or less at 24VDC Leakage current 100A
The tightening torque should be 0.05 to 0.1Nm. 5 to 6 Holding screw (included with the auto switch) Watchmaker's screw driver 27 Series MY2 Auto Switch Specifications Auto Switch Common Specifications Type Solid state switch Reed switch Leakage current Operating time Impact resistance 3-wire: 100A or less, 2-wire: 0.8mA or less None 1ms or less 1.2ms 300m/s2 1000m/s2 Insulation resistance
Bearing Style: M (Slide Bearing), Bore Size: 25mm, Thread: TN (NPT), Stroke: 100mm
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7,