SMC Corporation of America
Elite Part Number Search
Search Results "CXSM20-60-Z76"

/Z80 Auto Switch Specifications With indicator light D-Z73 D-Z76 Auto switch part no.

x 1.25 40 145 115 75 60 31.5 30 20 24 M39 x 1.5 CHN M8 x 1.25 M10 x 1.5 50 185 145 95 80 40 40 25 26 M48 x 1.5 H +0.4 +0.1 D M5 x 0.8 M6 x 1.0 25 76 60 41 32 16 16 12.5 20 M16 x 1.5 CHM M5 x 0.8 M6 x 1.0 31.5 90 70 50 40 20 20 16 20 M20 x 1.5 B J M6 x 1.0 M8 x 1.25 40 145 115 75 60 31.5 30 20 24 C-series M24 x 1.5 K CHSm M6 x 1.0 M8 x 1.25 40 145 115 75 60 31.5 30 20 24 M30 x 1.5 A M8 x

RZQ Auto Switch Internal Circuit D-Z73 MI W S LED Brown OUT (+) Brown CEP1 Contact protection box CD-P11 CD-P12 Resistor Reed switch Zener diode CE1 Weight OUT () Blue Blue CE2 (g) D-Z76 Auto switch model D-Z73 D-Z76 D-Z80 ML2B 10 9 7 0.5 DC (+) Brown LED Lead wire length (m) 55 49 31 3 (+) C J G5-S Resistor 50 5 Load Reed switch OUT Black Reverse current prevention diode DC power supply

MLGP RLQ Weight MLU (g) D-M5NT D-M5PT Auto switch model ML1C Auto Switch Internal Circuit 0.5 Lead wire length (m) 3 60 60 D5 95 95 DC (+) Brown -X Timer Operation Main circuit of switch Main circuit of switch OUT Black 20Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning.

Mass (g) D-M5NT D-M5PT Auto switch model Auto Switch Internal Circuit 0.5 Lead wire length (m) 3 60 60 D-M5NTL 5 95 95 DC (+) Brown Timer Operation Main circuit of switch Main circuit of switch OUT Black Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4-TT TH TD TF TS 4-TR TY TC TA TL TU TU Z TD-H10 (Hole) Bore size (mm) TA TL TU TC TX TE TO TR TT TS TH TF TY Part no. 40 +0.070 0 85 9 60 60 10 102 119 17 17 12 45 62 93 80 15 CA2-S04 50 +0.070 0 95 9 60 60 10 112 129

60 16 The above values are the maximum allowable values for moment and load.

Speed 600 mm/s 0.01 0.01 20 40 0 60 20 40 0 60 80 20 40 0 60 Moment (Nm) Moment (Nm) Moment (Nm) Vertical Operation Intermediate Stops The cushion effect (smooth start-up, soft stop) exists only before the stroke end in the stroke ranges indicated in the table below.

Table (1) (mm) 50 63 Bore size (mm) 6 to 26 14 to 54 87 60 MY1W A to A Max. B to B Max.

Y = 6.525 x 9.8 x 29.6 x 103 = 1.89 (Nm) Y Load factor 2 = M3/M3max = 1.89/60 = 0.03 MTS m4 M3 MY 5.

C76 Auto Switch Internal Circuit D-Z73 C85 LED Brown OUT (+) Brown C95 Contact protection box CD-P11 CD-P12 Resistor Reed switch Zener diode CP95 Weight OUT () Blue Blue NCM (g) D-Z76 Auto switch model D-Z73 D-Z76 D-Z80 NCA 10 9 7 0.5 DC (+) Brown LED Lead wire length (m) 55 49 31 3 (+) DResistor 50 5 Load Reed switch OUT Black Reverse current prevention diode DC power supply -X () Dimensions

TE TH TL Z TD TS TO TT TU TX TR TY 35 45 45 60 60 75 74 97 109 130 150 184 12 16 16 20 20 25 50 63 75 90 110 132 10 12 12 14 14 17 46 52 65 75 95 114 62 80 80 100 100 120 47 60 60 80 80 100 8.5 10 10 15 15 15 C95-S03 C95-S04 13 17 17 22 22 24 62 80 92 110 130 158 7 9 9 11 11 13.5 49 58 71 87 110 136 95 106.5 122 129.5 150 160 12 17 17 20 20 26 45 60 60 70 70 90 32 40 50 63 80 100 C95-S06

Output circuit Surge voltage 24 V 0 V sol.1: Energized 60 V R Surge voltage Internal circuit 24 V 0 V sol.2: De-energized 60 V R Surge voltage 24 V 0 V Large capacity load: Energized 60 V R Relay Power supply circuit breaker 24 VDC Figure 1.

MM L1 E1 E1 L1 NDH10 NX U1 ND H10 NZ MM R1 U1 R1 NX A A1 32 40 50, 63 80 100 32 40 50, 63 80 100 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 20 22 28 40 40 30 40 50 65 65 14 19 24 26 26 20 22 28 40 40 30 40 50 60 60 12 16 19 24 34 34 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14

OUT(+) Brown(Red) Contact protection box Resistance Reed switch Zener diode to CD-P11 Dimensions OUT() Blue(Black) CD-P12 Blue(Black) D-Z73 D-Z76, Z80 D-Z76 DC(+) Brown(Red) (+) LED Power voltage Resistance Reed switch Load OUT Black(White) Reverse flow prevent diode DC() Blue(Black) () D-Z80 Contact protection box OUT() Brown(Red) Reed switch to CD-P11 CD-P12 OUT( ) Blue(Black) Operation

32 7 40 93 148 64 26 CY1R50 25 110 8.6 10 M8 x 1.25 15 159 48 42 60 41 10 50 113 176 82 30 CY1R63 24 118 8.6 10 M8 x 1.25 16 171 60 48 70 47 10 60 121 188 94 32 With auto switch CY1R6H .

B TA TL TU TC TX TE TO TT TR TS TH TF TDH10 MB-S03 32 40 50 63 80 100 125 32 40 50 63 80 100 125 +0.070 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 +0.084 0 +0.084 0 47 60 60 80 80 100 115 46 52 65 75 95 114 136 45 60 60 70 70 90 105 8.5 10 10 15 15 15 18.5 62 80 92 110 130 158 186 50 63 75 90 110 132 160 74 97 109 130 150 184 212 12 17 17 20 20 26 26 13 17 17 22 22 24 24 10 12 12 14 14 17 25 35

60 80 105 110 115 1, 2 A5 15 + 55 (n 2)/2 20 + 55 (n 2)/2 60 + 55 (n 4)/2 60 + 55 (n 4)/2 80 + 55 (n 4)/2 105 + 55 (n 4)/2 110 + 55 (n 4)/2 115 + 55 (n 4)/2 n A6 n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 n = 4, 8, 12, 16 15 20 60 70 85 110 115 120 2 20 + 55 (n 2)/2 25 + 55 (n 2)/2 65 + 55 (n 4)/2 70 + 55

(Example) The overall length of the cylinder tube for CHDKDB50-60-XC61, is equivalent to 75 strokes.