0.6 MPa 100 50 Overhang H (mm) Overhang H (mm) 80 0.3 MPa 0.3 MPa Pressure 0.2 MPa Pressure 0.2 MPa 0.3 MPa 40 0.4 MPa 0.4 MPa 60 0.5 MPa 0.5 MPa 30 0.3 MPa 0.7 MPa 0.7 MPa 0.6 MPa, 0.7 MPa 0.6 MPa, 0.7 MPa 0.4 MPa 0.5 MPa 0.6 MPa, 0.7 MPa 0.4 MPa 40 20 0.5 MPa 20 10 0 10 20 30 40 50 60 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) MHZ2-20/11-MHZ2-20 80 Pressure 0.2 MPa
30 40 Load (N) 0 10 20 30 40 Load (N) 0 10 20 30 50 Load (N) 40 10 10 10 L = 100 mm L = 100 mm L = 100 mm Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) MXP10-10 MXP10-20 MXP10-10 MXP10-20 0.04 0.03 0.08 MXP10-10 MXP10-20 MXP10-10 MXP10-20 MXP10-10 MXP10-20 MXP10-10 MXP10-20 0.03 0.06 0.02 0.02 0.04 0.01 0.01 0.02 0 0 0 80 20 40 60 80 Load (N
Auto switches are shipped together but not assembled. 6 10 16 20 25 32 6 mm 10 mm 16 mm 20 mm 25 mm 32 mm Action D Double acting Port thread type Type M5 x 0.8 Rc1/8 NPT1/8 G1/8 Bore size 6, 10, 16, 20, 25 32 32 32 Symbol Standard stroke (mm) 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50, 60 5, 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 Nil TN TF Applicable Auto Switches/Refer
20 10 0.6 MPa 0.6MPa 8 15 Gripping force N Gripping force N 0.5MPa 0.5MPa 6 10 0.4MPa 0.35MPa 0.4MPa 0.35MPa 4 5 2 0 10 20 30 40 50 0 10 20 30 40 50 60 Gripping point L mm Gripping point L mm MRHQ16S MRHQ16C 60 Pressure 0.7MPa 40 Pressure 0.7MPa 50 0.6MPa 0.6MPa 40 30 Gripping force N Gripping force N 0.5MPa 0.5MPa 30 0.4MPa 20 0.4MPa 20 0.3MPa 0.3MPa 10 10 MHZ 0.25MPa 0.25MPa 0 10 20 30
force (N) Gripping force (N) 0.5 MPa 0.4 MPa 20 20 0.4 MPa 0.3 MPa 0.3 MPa 10 10 0.2 MPa 0.2 MPa 0 10 20 30 40 50 0 10 20 30 40 50 L: Gripping point length (mm) Gripping point L (mm) Gripping point L (mm) MHR2-20/MDHR2-20 MHR2-20/MDHR2-20 Indication of effective gripping force The effective gripping force shown in the graphs to the right is expressed as F, which is the thrust of one finger
MHR2-10/MDHR2-10 MHR2-20/MDHR2-20 50 60 Overhang distance H (mm) Overhang distance H (mm) 50 40 Pressure 0.2 MPa Pressure 0.2 MPa 40 30 30 0.3 MPa External grip 0.3 MPa 0.4 MPa 20 0.4 MPa 20 0.5 MPa 0.5 MPa 0.6 MPa 10 0.6 MPa 10 0 10 20 30 40 50 0 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-
$2 are for 20 to 40.
MXQ16-20 MXQ16-20 MXQ16-20 MXQ16-20 D0.02 0.04 MXQ16-10 MXQ16-10 MXQ16-10 0.01 MXQ16-10 MXQ16-10 -X 0 0 400 100 200 300 150 150 50 100 200 50 100 200 0 20Load (N) Load (N) Load (N) Data 20 20 20 Lr = 160 mm 0.08 MXQ20-125 MXQ20-150 MXQ20-125 MXQ20-125 MXQ20-10 MXQ20-10 MXQ20-20 MXQ20-20 MXQ20-30 MXQ20-30 MXQ20-10 MXQ20-20 MXQ20-30 MXQ20-50 MXQ20-50 MXQ20-50 MXQ20-75 MXQ20-40 0.12 MXQ20-40
30 30 60 0.3 MPa 0.4 MPa 40 0.5 MPa 0.6 MPa 20 20 40 0.6 MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Note) Distance to the gripping point L of single acting type is shortened by spring return.
30 30 60 0.3 MPa 0.4 MPa 40 0.5 MPa 0.6 MPa 20 20 40 0.6 MPa 20 20 10 10 50 60 10 0 0 20 50 60 10 0 20 30 40 100 120 20 0 20 30 40 100 80 60 40 40 60 80 Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Gripping point L (mm) Note) Distance to the gripping point L of single acting type is shortened by spring return.
MI-A0801-10 MI-A0801-20 MI-A1201-10 MI-A1201-20 MI-A1201-30 MI-A2001-10 MI-A2001-20 MI-A2001-30 MI-A2501-30 MI-A2501-50 MI-A3201-30 MI-A3201-50 MI-A0802-10 MI-A0802-20 MI-A1202-10 MI-A1202-20 MI-A1202-30 MI-A2002-10 MI-A2002-20 MI-A2002-30 MI-A2502-30 MI-A2502-50 MI-A3202-30 MI-A3202-50 MI-A0803-10 MI-A0803-20 MI-A1203-10 MI-A1203-20 MI-A1203-30 MI-A2003-10 MI-A2003-20 MI-A2003-30 MI-A2503
MI-A0801-10 MI-A0801-20 MI-A1201-10 MI-A1201-20 MI-A1201-30 MI-A2001-10 MI-A2001-20 MI-A2001-30 MI-A2501-30 MI-A2501-50 MI-A3201-30 MI-A3201-50 MI-A0802-10 MI-A0802-20 MI-A1202-10 MI-A1202-20 MI-A1202-30 MI-A2002-10 MI-A2002-20 MI-A2002-30 MI-A2502-30 MI-A2502-50 MI-A3202-30 MI-A3202-50 MI-A0803-10 MI-A0803-20 MI-A1203-10 MI-A1203-20 MI-A1203-30 MI-A2003-10 MI-A2003-20 MI-A2003-30 MI-A2503
20 Stroke Reading Cylinder Series CE1 Construction 12, 20 32 @7 @4@8 @0 oi @3 !
20 Stroke Reading Cylinder Series CE1 Construction 12, 20 32 @7 @4@8 @0 oi @3 !
VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
Minimum Auto Switch Mounting Stroke (mm) Auto switch model Bore size (mm) D-A9 A9V D-M9 D-M9V D-F9W D-F9WV D-F9BAL Number of auto switches 2 pcs. 10 5 15 10 20 10 15 20 1 pc. 5 5 15 5 20 10 15 2 pcs. 10 5 10 10 20 10 10 25,32,40,50 1 pc. 5 5 10 5 20 10 10 2 pcs. 10 5 10 10 15 10 10 63 1 pc. 5 5 10 5 15 5 5 Besides the models listed in How to Order, the following auto switches are applicable
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.
Example) For setting the gripping force to be at least 20 times the work weight; Required gripping force = 0.05 kg x 20 x 9.8 m/s2 = 10 N min.