CG3 JMB MB MB MB1 CA2 CS1 CS2 Operating Range [mm]
Auto switch model Auto switch model With 1 pc. 40 50 63 Different surfaces Same surface D-P3DWA D-P4DW D-P79WSE D-P74 D-P3DWA D-P4DW D-P79WSE D-P74 5.5 5.5 5.5 4 4 4.5 50 50 8 9 9.5 D-M9 D-M9W D-M9A Note1) When two D-P3DWA are mounted to the cylinder with stroke 50 mm, mount them on different surfaces. Note2) The standard strokes of CKG1 are 50, 75, 100, 125 and 150 mm.
For D-P3DWA/P4DW, 40 to 100 are available. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649. Please contact SMC for auto switches, auto switch proper mounting positions and operating ranges other than the above. The D-A9/M9/P3DWA auto switches are shipped together, (but not assembled).
For the D-P3DWA, refer to the WEB catalog. The D-A9/M9/P3DWA auto switches are shipped together, (but not assembled).
Operating Range [mm]
Operating Range [mm]
Lock: With Lock, Body Shape: Mounting Tap: 4xM10x1.5, Pin Hole: 2xø8H7, Mounting Surface: 90° from Port Location, Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 12.5mm, Guide Pin Shape: Round Type, Clamp Arm Position: Same Direction as Port, Clamping Height: High Type, Shim: With 3mm Shims, Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic Field Resist., 2 Wire, Lead Wire
Lock: L (With Lock), Body Shape: D (Mounting Tap: 4xM10x1.5, Pin Hole: 2xø8H7), Mounting Surface: A (90° from Port Location), Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 125 (12.5mm), Guide Pin Shape: R (Round Type), Clamp Arm Position: A (Same Direction as Port), Clamping Height: H (High Type), Shim: S (With 3mm Shims), Auto Switch: P4DW--Solid State, 2-color Indication, Magnetic
B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5 9.5 9 12 B 8 8.5 10.5 11.5 15.5 Hs 24.5 26 29 33 38.5 45.5 Hs Hs 22 24 26.5
D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-A9/A9V D-F7/F7V/J79/J79C/F7W/J79W/F7WV D-F7BA/F7BAV/F79F/F7NT D-A7/A80/A7H/A80H/A73C/A80C/A79W D-P3DWA Applicable auto switch Bore size (mm) 12 to 63 20, 25 32 to 63 32 to 63 Auto switch mounting bracket part no.
Solid state auto switch D-M9 Reed auto switch D-A9 Magnetic field-resistant auto switch D-P3DWA 559-1 A Stopper Cylinder RSQ Series Various rod end configurations Shape can be selected to suit the intended application.
(Red Green Red) PLC: Programmable Logic Controller D-P3DWA (With indicator light) D-P3DWA Auto switch model 24 VDC relay, PLC Applicable load 24 VDC Load voltage 6 to 40 mA Load current 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current 40 ms or less Operating time Operating range . Red LED illuminates. Proper operating range . Green LED illuminates.
(Red Green Red) PLC: Programmable Logic Controller D-P3DWA (With indicator light) D-P3DWA Auto switch model 24 VDC relay, PLC Applicable load 24 VDC Load voltage 6 to 40 mA Load current 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current 40 ms or less Operating time Operating range . Red LED illuminates. Proper operating range . Green LED illuminates.
D-X 543 C(L)KQG32 Series Auto Switch Mounting 1 Auto Switch Mounting Height Applicable cylinder: C(L)KQG32-X2081 C(L)KQG32-X2082 For D-P3DWA D-P3DWA 26 32.5 D-P4DW 17 20 or more 35 or more 41.5 D-M9 D-M9W D-A9 Note) Allow 20 mm or more space at the cylinder head side to secure the minimum bending radius of the auto switch lead wire.
D-P3DWA A B Auto switch Hs Ht Auto Switch Proper Mounting Position (mm) Auto switch model D-P3DWA RSQ B 43 Hs 35 Ht A Bore size RSG 50 63 80 19 6.5 21 10 48.5 44 RS2H RS2H 35 17 56.5 54 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
Tightening torque of the hexagon socket head set screw (M4 x 0.7) shall be 1 to 1.2Nm. 23 - < Applicable Auto switches > Solid state switch D-P3DWA How to mount and move the auto switch Fig. 11 Mount the auto switch mounting bracket 2 to the tie rod.
Auto switch operating range (mm) Bore size (mm) Auto switch model 20 25 32 40 50 63 80 100 D-A9(V) 9 9 9 9.5 9.5 11 10.5 10.5 D-M9(V) D-M9W(V) 5.5 5 6 5.5 6 6.5 6 7 D-M9A(V) D-Z7/Z80 10 10 10.5 10.5 10.5 11.5 11.5 12 D-Y5/Y6 D-Y7P(V) 7.5 7 6.5 6 7 8 9.5 10 D-Y7W(V) D-Y7BA D-P3DWA 5.5 6 6.5 6 6.5 6 6 D-P3DW 6 5.5 5.5 5.5 6.5 7.5 7.5 D-P4DW 5 4 4 5 4 4 * Since this is a guideline including
SMC's CLK2 series is a perfect choice for holding applications in either a clamped or unclamped state. CLK2 cylinders have a compact lock mechanism which minimizes the extension of the length dimension (2mm shorter), while maintaining the mounting interchangeability with the CLK1 existing product line. The CLK2 is capable of being locked at any position within the entire stroke. A dedicated
Lock: With Lock, Body Shape: Mounting Tap: 2xM10X1.5, Pin Hole: 2xø8H7, Mounting Surface: 90° from Port Location, Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 12.7mm, Guide Pin Shape: Round Type, Clamp Arm Position: 270° From Port, Clamping Height: High Type, Shim: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, High Hardness Guide Pin: -
Lock: With Lock, Body Shape: Mounting Tap: 2xM10X1.5, Pin Hole: 2xø8H7, Mounting Surface: 90° from Port Location, Bore Size: 50mm, Port Thread: Rc, Guide Pin Diameter: 14.8mm, Guide Pin Shape: Round Type, Clamp Arm Position: Same Direction as Port, Clamping Height: High Type, Shim: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, High Hardness Guide Pin: -