Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting: Double
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting: Double
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting: Double
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 75, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting: No
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting:
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting:
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 40, Stroke S(mm): 125, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: M9B, Lead Wire Length(m): 3, The number of the switches: 2, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip fitting:
Magnet Type: Built-in Standard Magnet Type, Clevis: 16.5mm, Bore: 40mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: None, Option: Limit Switch Mounting Base, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: -
Magnet Type: Built-in Standard Magnet Type, Clevis: 16.5mm, Bore: 40mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: I [Single Knuckle Joint (M6 w/o Tap)], Option: Limit Switch Mounting Base, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: -
Magnet Type: Built-in Standard Magnet Type, Clevis: 16.5mm, Bore: 40mm, Thread: Rc1/4, Stroke: 50mm, End Bracket: I [Single Knuckle Joint (M6 w/o Tap)], Option: Limit Switch Mounting Base, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: -
Magnet Type: Built-in Standard Magnet Type, Clevis: 16.5mm, Bore: 40mm, Thread: Rc1/4, Stroke: 75mm, End Bracket: Y [Double Knuckle Joint (M6 w/o Tap)], Option: Limit Switch Mounting Base, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire: 3m, Number: -
Magnet Type: -, Clevis: -, Bore: -, Thread: -, Stroke: -, End Bracket: -, Option: -, Auto Switch: -, Lead Wire: -, Number: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM CK CLAMP CYLINDER, ACTUATOR, CK CLAMP CYLINDER, MC, 40MM CK CLAMP CYLINDER, 5.15636 lb
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base)
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: B (19.5mm), Bore: 63mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base)
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: B (19.5mm), Bore: 63mm, Thread: TN (NPT1/4), Stroke: 100mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base)
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: A (16.5mm), Bore: 50mm, Thread: TN (NPT1/4), Stroke: 100mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base)
Magnet Type: G1 (Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch), Clevis: B (19.5mm), Bore: 50mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: YA (Double Knuckle Joint, M6 w/Tap), Option: B (Limit Switch Mounting Base)
Operation Method: Straight Advancing Stroke, Cylinder Diameter(Ø): 50, Stroke S(mm): 100, Support Type: Clevis, Rod Tip Shape: [Others] Clevis Type, Max. Pressure(MPa): 1, Operating Temperature Range(°C): -10~-60, Auto Switches: Without switch, Lead Wire Length(m): -, The number of the switches: -, Specification: Standard built-in magnet, Port Screw Type: Rc1/4, Clevis width(mm): 16.5, Tip
Magnet Type: Built-in Standard Magnet w/Magnetic Field Resistant Auto Switch, Clevis: 19.5mm, Bore: 63mm, Thread: Rc1/4, Stroke: 100mm, End Bracket: Double Knuckle Joint, M6 w/Tap, Option: Limit Switch Mounting Base, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -