SMC Corporation of America
Elite Part Number Search
Search Results "CDUK10-10S-A96"

MHZ2-25S/MHZL2-25S MHZ2-6S/MHZA2-6S 4 80 Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 0.6 MPa 3 60 F 0.6 MPa 0.5 MPa 0.5 MPa 2 40 0.4 MPa 0.4 MPa 0.3 MPa 1 20 0.3 MPa 0.25 MPa F 0 10 20 30 0 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) External Grip MHZ2-10S/MHZL2-10S MHZ2-32S MHZA2, MHZ2, MHZL2 12 250 Pressure 0.7 MPa 10 Pressure 0.7 MPa 200 0.6

Magnet: D (Built-in Magnet), Bore Size: 10 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 10 mm, Action: S (Single Acting Spring Return)

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Cushion: Rubber

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.18~0.7, Cushion: Rubber

Magnet: D (Built-in Magnet), Bore Size: 10 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 10 mm, Action: S (Single Acting Spring Return), Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal

Magnet: Built-in Magnet, Bore Size: 10 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 10 mm, Action: Single Acting Spring Return, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 12mm, Stroke: 10mm, Action: S (Single Acting Spring Return), Option: Standard (Rod End Female Thread), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 10mm, Action: Single Acting Spring Return, Option: Standard (Rod End Female Thread), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Thread: -

A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch. ( ): Dimension of the D-A96. A and B are the dimensions from the end of the head cover/rod cover to the end of the auto switch. D-M9V D-M9MV D-M9AV D-A9V Hs Hs Auto switch Auto switch 17.5 17.5 A 20 (22) B A 22 B ( ): Dimension of the D-M9AV.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Auto Switch Internal Circuit D-A90 Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A93 D-A96 Auto switch part no. 0.5 6 6 8 41 Lead wire length (m) 3 30 30 D-A93 LED diode Brown OUT (+) Brown Contact protection box Resistor Dimensions Unit: mm Reed switch Zener diode CD-P11 D-A90/D-A93/D-A96 CD-P12 OUT () Blue Blue D-A96 DC (+) Brown Indicator

A96V A96 V V IC circuit Reed auto switch Yes 200 V A72 A72H V V Grommet 100 V A93V2 A93 A93V2 A93 V V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indicator) Grommet Yes A79W V V Auto Switch Made to Order 1 Water resistant

NPN) Grommet 24 V A96V A96 5 V IC circuit A93V A90V A93 A90 Relay, PLC IC circuit 100 V 2-wire 12 V No 100V or less Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance. Consult with SMC regarding water resistant types with the above model numbers.

44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

Switches with an indicator light (except D-A56/A76H/ A96/A96 V/C76/E76A/Z76) If auto switches are connected in series as shown below, please note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.)

BQ-1 BQ-2 BQ2-012 Mass (g) 1.5 1.5 5 179 Series CHmQB/CHmQWB How to Mount and Move the Auto Switch Solid state D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed D-A90(V), A93(V), A96(V) 20 1.

A96V A96 V V IC circuit Reed auto switch Yes 200 V A72 A72H V V Grommet 100 V A93V*2 A93 A93V*2 A93 V V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indicator) Grommet Yes A79W V V *1 Water resistant type auto switches can be

47 C 11 21 27 34.5 35.5 44.5 A 19.5 29.5 35.5 43 44 53 6 10 15 20 25 32 Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.

CXSJ10 D B (mm) D-A90, D-A96 25.7 29.7 3.2 D-A93 25.7 27.2 5.7 D-F9 29.7 2.8 19.7 7.2 Symbol A B Note) C D A C Note) For D-A90, D-A96, and D-A93, only outward electrical entry (D dimension) is available.

load Load voltage D-A90/D-A90V IC circuit, Relay, PLC 24 VAC/DC or less 50 mA None 1 or less (including lead wire length of 3 m) CE marking 48 VAC/DC or less 40 mA 100 VAC/DC or less 20 mA Maximum load current Contact protection circuit Internal resistance Standards D-A93(V)/D-A96(V) (With indicator light) Auto switch model Applicable load Load voltage D-A93/D-A93V Relay, PLC 24 VDC D-A96