Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8P,
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8P,
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: M9NW
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet
Double Acting/Single Acting 1in=25.4mm Without magnet/CUJB8 Note) The angular position of the width across flats is not fixed with respect to the tube. 2-M3 x 0.5 (port size) M3 x 0.5 effective depth 6 Element 3 6 3.5 Width across flats 10 Width across flats 4.5 10 11 8 5 11h9 21 8 2.5 2-3.3 through 2-3.3 through 19 + Stroke 13 + Stroke 6.5 + Stroke 3 13 7 Single acting 3 3 Built-in magnet/CDUJB8
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 8mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 8mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 8mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 8mm, Stroke: 6mm, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 8mm, Stroke: 6mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 8mm, Stroke: 6mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Model: MSQ, Type: B (Basic Type), Size: 7, Port Location: E (Front Port), Auto Switch: F8B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: F8B--Solid State , Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: Z (5m)
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.005 to Less than 0.01, Tube Nominal Diameter: 12, Valves: Not Provided, Allowable Kinetic Energy(J): 0.006, Operating Pressure
Sensor Type: Non-Contact, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Wiring type: 2-wire, Output Type: None, Electrical entry direction: Perpendicular, Lead wire length(m): 5, Connector Type: None, Made-to-order specifications: None
The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size
The CUJ miniature free mount series is a space saving compact cylinder. It is available in 4mm to 10mm bore sizes with stroke lengths up to 20mm for double acting and 10mm for single acting. Options include auto switch capabilities, double and single acting, mounting from 4 directions.Miniature free mount , Space saving compact cylinder , Available in 4mm to 10mm bore size