SMC Corporation of America
Elite Part Number Search
Search Results "CDUJB20-20D-F8B"

-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.

Type Model Features Applicable bore size (mm) Electrical entry (Fetching direction) D-A90 D-A90V D-F8N D-F8P D-F8B Grommet (In-line) Grommet (Perpendicular) Reed switch Without indicator light 8 to 40 Solid state switch Grommet (Perpendicular) With indicator light 8 Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 20, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 20, Stroke: 50mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 20, Stroke: 25mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 20, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 20, Stroke: 25mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

(Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Auto Switches: F8B

(Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Auto Switches: F8B

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 20, Stroke: 20mm, Action: D (Double Acting)

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Auto Switches

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 16, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: S (Axial Mounting), Bore Size: 20, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 12, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 10, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 12, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -