Magnet: D (Built-in), Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 80 mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: Z (5 m)
Magnet: D (Built-in), Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 80 mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: Z (5 m)
Magnet: Built-in, Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 80 mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 0.5 m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in, Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 80 mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 3 m, Number: -
Magnet: Built-in, Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 80 mm, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: 5 m, Number: -
Magnet: Built-in, Bore Size: 25 mm, Port Thread: M5x0.8; Rc1/8 for ø32, Stroke: 80 mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Prewired Connector: 5 m, Number: -
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread
F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid
A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L
When 800.00[mm](80d=13880h) is input. (5) 6023h 0-31 Target position 6023h: Target position = 00013880h Index 6030h: Alarm Index Bit Signal name Description Alarm code shown as a 3 digit decimal number when read numerical data is valid and alarm is generated. 5 Latest alarm code generated will be output to alarm 1. Alarm is updated by another alarm.
The READY flag turns ON. 2 5 (Unused) Set always OFF(0) 6-7 (Unused) Set always OFF(0) 3 0-7 (Unused) Set always OFF(0) Byte4-7: Current position Byte Signal name Description Current position of the actuator is shown in multiples of 0.01mm when numerical data can be read. (5) 4 5 E.g.) 800.00[mm](80d=13880h) is output.
=13880h 4Byte = 80h 5Byte = 38h 6Byte = 01h 7Byte = 00h 4 5 6 7 Byte8,9 Byte 1[mm/s] *5 300[mm/s]300d=012Ch 8Byte = 2Ch 9Byte = 01h 8 9 *5 21(P.85 35 - Byte10,11: Byte 10 1[%] *5 11 Byte12-15 Byte 12 0.01[mm] *5 800.00[mm]80d=13880h 12Byte = 80h 13Byte = 38h 14Byte = 01h 15Byte = 00h 13 14 15 Byte16-19 Byte 16 1 10 3 *5 1 1234 17 2 1 2 0 18 3 3 0 0 4 0 0 0 * 16.2.P.65
Example) 40D-A3C-4, 50D-A3C-5, 63D-A3C-6, 80D-A3C-8, 100D-A3C-10 To order the mounting brackets separately, use the part number shown above.
Example) 40D-A3C-4, 50D-A3C-5, 63D-A3C-6, 80D-A3C-8, 100D-A3C-10 To order the mounting brackets separately, use the part number shown above.
CL Bore size (mm) 40 50 63 80 100 Part No. of lock unit MLGC CNA 40D-UA P 0.3MPa CNA 50D-UA CNA CNA 63D-UA Old CNA 80D-UA CB CNA100D-UA CV/MVG wHow to replace lock unit 1) Loosen the tie-rod nut (4 pcs.) on head cover of cylinder by using socket wrench. Refer to table below for applicable sockets.
(Example) 40D-A3C-4, 63D-A3C-6, 100D-A3C-10 50D-A3C-5, 80D-A3C-8 To order the mounting brackets separately, use the part number shown above.
(Example) 40D-A3C-4 50D-A3C-5 63D-A3C-6 80D-A3C-8 100D-A3C-10 When other brackets are ordered separately, order by the above part numbers. Stainless steel mounting screw kit A set of stainless steel mounting screws (with set screws) described below is available and can be used as required by the operating environment.
(Example) 40D-A3C-4, 63D-A3C-6, 100D-A3C-10 50D-A3C-5, 80D-A3C-8 To order the mounting brackets separately, use the part number shown above.
L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.