Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 12mm, Stroke: 50mm, Option: C (Rubber Bumper), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m
Magnet: Built-in, Mounting: Foot, Bore Size: 12mm, Stroke: 50mm, Option: Rubber Bumper, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 20mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 20mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 20mm, Option: Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 25mm, Stroke: 20mm, Option: Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -
Magnet: D (Built-in), Mounting: B (Through Hole), Bore Size: 25mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 20mm, Body Option: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5M
Magnet: Built-in, Mounting: Through Hole, Bore Size: 25mm, Thread: M5x0.8 (20-25 Bore); Rc (32-100 Bore), Stroke: 20mm, Body Option: Rod End Male Thread, Locking Direction: Forwarding Stroke Lock, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5M, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product, and replaced byCDQ2B32-20DMZ-A93V-XB9C6
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
A93 A93V A93 V V V No 100 V or less A90V A90 A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+)
OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch Note 3) OUT ( ) Blue Mass (g) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A93, A93V 6 6 6 6 8 8 (m) Lead wire length 0.5 LED 30 30 30 30 41 41 3 Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 Resistor Dimensions Reed switch (mm) Zener diode D-A90/D-A93/D-A96 OUT () Blue Blue (Black) 2 2.8 4.5 2.7 4 22 (24.5) D-A96,
Applicable load IC circuit, Relay, PLC Load voltage 24 V AC/DC or less 48 V AC/DC or less 100 V AC/DC or less Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None Internal resistance D-A93/D-A93V/D-A96/D-A96V (with indicator light) 1 or less (including lead wire length of 3 m) D-A93/D-A93V D-A96/D-A96V Auto switch part no.
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 12mm, Stroke: 10mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 12mm, Stroke: 10mm, Option: M (Rod End Male Thread)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 12mm, Stroke: 100mm, Option: C (Rubber Bumper)