SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2XA40-75D-A93L"

Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Port Thread Type: Rc (or Metric), Stroke: 75mm, Option: Male Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m

.: CQ2B50-57D 18 mm width spacer is installed in the standard CQ2B50-75D. B dimension is 115.5 mm. Part no. CQ2B50-57D-XB10 Makes 57 stroke tube. B dimension is 97.5 mm. Example Air-hydro type is excluded. In the case of spacer type, intermediate stroke with damper for 40 to 100, it can be manufactured by 5 mm intervals in 5 mm and 55 to 95 mm.

Example) 18 mm width spacer is installed in the standard cylinder 10CQ2XB40-75D to make 10CQ2XB40-57D. 12 16 20 25 Fluid Proof pressure Maximum operating pressure Minimum operating pressure Air 1.5 MPa 1.0 MPa Rod end thread Nil M Standard (Rod end female thread) Rod end male thread 0.04 MPa 0.035 MPa Without auto switch: 10 to 70C With auto switch: 10 to 60C 1 to 200 mm/s Ambient and fluid

Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.

Example) For 10-CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke 10-CQ2XB40-75D cylinder. Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder. The total length of the cylinder is the same as the longer standard stroke.

NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.

A93 A93L F9NWZ (Example) (Example) (Example) 13 Rotary Table Series MSQ Specifications 10 20 30 50 70 100 200 Size Air (non-lube) Fluid Maximum operating pressure Minimum operating pressure 1MPa With adjustment bolt Note 1) 0.6MPa With internal shock absorber 0.1MPa Basic type 0.2MPa 0.1MPa High precision type 0 to 60C (with no condensation) Ambient and fluid temperature Rubber bumper With

L A93L Note) Refer to P. 177 to 179 for further information of auto switch. PLC: Programmable Logic Controller Specifications Specifications are same as the standard type.

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) M9NZ Refer to page 8-28-27 for additional details and applicable auto switches other than the above types.

wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93 3mL A93L

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Lead wire length symbols 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Refer to page 14 for additional details and applicable auto switches other than the above types.

Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L

L (Example) A93L 5m . Z (Example) F9NWZ Note 2) Solid state switches marked with a "" symbol are produced upon receipt of order. D-9 auto switch can also be mounted.

This is a legacy product, and replaced byCDG1BH63-250Z-A93L, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, PE, 63MM CG DBL-ACT AUTO-SW, 6.11782 lb

This is a legacy product, and replaced byCDQ2A32-100DZ-A93L, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, 1.55172 lb

This is a legacy product, and replaced byNCDQ2D50-50DMZ-A93L

This is a legacy product, and replaced byMGPM32-75Z-A93L, CYL, COMPACT GUIDE, SLIDE BRG, ACTUATOR, MGP COMPACT GUIDE CYLINDER, LM, 32MM MGP SLIDE BEARING, 5.50152 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040032MGPM32??1.69??2.072.472.853.243.624.004.385.336.096.867.62