SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2L32-25DM-A93L"

A93 A93L F9NWZ (Example) (Example) (Example) 13 Rotary Table Series MSQ Specifications 10 20 30 50 70 100 200 Size Air (non-lube) Fluid Maximum operating pressure Minimum operating pressure 1MPa With adjustment bolt Note 1) 0.6MPa With internal shock absorber 0.1MPa Basic type 0.2MPa 0.1MPa High precision type 0 to 60C (with no condensation) Ambient and fluid temperature Rubber bumper With

NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.

Magnet: D (Built-in), Mounting: L (Foot), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: M (Rod End Male Thread)

Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: -, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: -, Mounting: -, Bore Size: -, Stroke: -, Option: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: D (Built-in), Mounting: L (Foot), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m

Magnet: D (Built-in), Mounting: L (Foot), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting

Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 25mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Mounting

This is a legacy product, and replaced byNCDRA1BS50-90CZ-A93L NCRA ROTARY ACTUATOR. NCRA 50 SGL/DBL ROD W/AUTO-SW. ACTUATOR. 50MM NCRA DBL-ACT AUTO-SW. 3.30000 lb. NE.

This is a legacy product, and replaced byMGPM20-125Z-A93L MGP COMPACT GUIDE CYLINDER. CYL, COMPACT GUIDE, SLIDE *LQA. ACTUATOR. 20MM MGP SLIDE BEARING. 3.57060 lb. HM.

F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A93 (Example) A93L

Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil (Example) A93 3 mL A93L

switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols: 0.5 mNil (Example) A93 3 m L (Example) A93L

Load voltage Auto switch model Electrical entry direction Indicator light Electrical entry Special function Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12V In-line Yes Grommet 24V 100V 12V Reed switch 2-wire Relay, PLC A93 3-wire (NPN) M9N Yes Grommet 24V Solid state switch Relay, PLC 2-wire 12V M9B Lead wire length symbols: 0.5mNil (Example) A93 3 m L (Example) A93L

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) M9NZ Refer to page 8-28-27 for additional details and applicable auto switches other than the above types.