Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: L (Shipped Together), Rod End Bracket: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: Shipped Together, Rod End Bracket: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: Shipped Together, Rod End Bracket: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

0 MGP CY CX CK1 C(L)K CDJZ2B10/16-Z-B C(L)KU CKQ Component Parts CKZ2N No.

(Z) Solid state auto switch M9P(M)(L)(Z) D-M9P(M)(L)(Z) M9B(M)(L)(Z) D-M9B(M)(L)(Z) A90(L) D-A90(L) Reed auto switch (Not applicable to flange size 16) A93(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

(Except 50) MY1MW16/20/50/63 MY1CW16/20/50/63 L L L L L L R R R R R R R L L R R R L L L R Slide table operating direction MY1MW25/32/40 MY1CW25/32/40 L L This port is not available for use. (Except 32, 40) L L L L L L L L R R R R R R R R L L R R L L L R Slide table operating direction 8-12-3 4 Series MY1W Specific Product Precautions 2 Be sure to read before handling.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

(V), A93(V), A96(V) Auto switch Set screw (Unused) Auto switch mounting screw M3 x 0.5 x 8 L (Attached to the cylinder) e 1.

Applicable bore size A1 L L1 MM Y-J010C 10 8 15.2 21 M4 x 0.7 Part no. Applicable bore size A1 L1 MM NDH10 NX R1 U1 Part no.

Note 4) Figures in ( ) in the table W are D-A93.

Note 4) ( ) in column W is the dimensions of D-A93.

m Dd9 L (Drill through) 3 x 18 l 4 x 25 l 4 x 35 l 4 x 36 l 0.040 0.076 CD-M03 CD-M05 CD-M08 CDP-7A 10 14 22 25 20, 25 32, 40 50, 63 80 3 4 4 4 4 4.5 5 5 36 51 72 78 44 60 82 88 0.050 0.093 0.065 0.117 0.065 0.117 l m L Note) When using cotter pins, flat washers are used together.