(Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
(Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
(Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
(Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
(Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 80mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: with Rubber Bumper, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Head Flange, Bore Size: 80mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: with Rubber Bumper, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: None, Mounting: Through-hole, Standard, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 45mm, Body Option: with Rubber Bumper, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental
Magnet: Built-in Magnet, Mounting: Head Flange, Bore Size: 80mm, Stroke: 45mm, Body Option: with Rubber Bumper, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 80mm, Stroke: 45mm, Body Option: with Rubber Bumper, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel
Magnet: None, Mounting: Both Ends Tapped, Bore Size: 40mm, Stroke: 45mm, Body Option: with Rubber Bumper, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support bracket
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
MGG series How to Order MGG XC6 Parts Changed to Stainless Steel Symbol Basic cylinder Guide unit -XC6 Flange, Front plate, Rear plate, Standard model no.
Use XC6 option to get stainless steel rod nut. Note 4) Non-rotating rod is stainless steel. Use XC6 option to get stainless steel rod nut. Note 5) Block mount not available in 7/8" and 1-1/4". Note 6) Block, Auto switch capable, S and T only available as special.