-75D -75D x 150 L x 165 L x 190 L 150 165 190 -100D -100D -100D x 175 L x 190 L x 215 L 175 190 215 819 Series CLQ Construction: 20 to 32 i o !
x 135L 135 -45D (M) -40D (M) x 110L 110 x 140L 140 -50D (M) -45D (M) x 115L 115 x 145L 145 -75D (M) -50D (M) x 120L 120 x 170L 170 -100 (M) -75D (M) x 145L 145 x 195L 195 -100D (M) CHmQB50-10D (M) x 170L 170 90 M6 x 90L -15D (M) 95 x 95L -20D (M) 100 x 100L -25D (M) 105 x 105L -30D (M) 110 x 110L -35D (M) 115 12 x 115L -40D (M) 120 x 120L -45D (M) 125 x 125L -50D (M) 130 x 130L -75D (M)
-75D -75D CDLQB25-5D -100D -100D -100D M10 x 125l x 130l x 135l x 140l x 145l x 150l x 155l x 160l x 165l x 190l x 215l -10D CDLQB40-10D CDLQB63-10D CDLQB100-10D -15D -15D -15D -15D -20D -20D -20D -20D -25D -25D -25D -25D 8.5 -30D -30D -30D -30D -35D -35D -35D -35D 16.5 15.5 8.5 -40D -40D -40D -40D -45D -45D -45D -45D -50D -50D -50D -50D -75D -75D -75D -100D -100D -100D 4 Series CLQ Construction
40D (M) x 110L 110 x 140L 140 -50D (M) -45D (M) x 115L 115 x 145L 145 -75D (M) -50D (M) x 120L 120 x 170L 170 -100 (M) -75D (M) x 145L 145 x 195L 195 -100D (M) CHQB50-10D (M) x 170L 170 90 CQ-M6 x 90L -15D (M) 95 x 95L -20D (M) 100 x 100L -25D (M) 105 x 105L -30D (M) 110 x 110L -35D (M) 115 12 x 115L -40D (M) 120 x 120L -45D (M) 125 x 125L -50D (M) 130 x 130L -75D (M) 155 x 155L -100D (M)
-50D -50D -50D x 140l x 165l -75D -75D -75D x 165l x 190l -100D -100D -100D x 190l x 215l 9-10-11 11 Series CLQ Construction: 20 to 32 i o !
The current part number for the old CDQ2B32-30D is “CDQ2B32-30DZ.” For this product, the auto switch mounting rail on the body has been changed to a round auto switch mounting groove. Cylinder body mounting is possible. A mounting bracket may be required if the auto switch in use is to be used as is. Check the auto switch model first.
(M) M5 x 70l x 75l x 80l x 85l x 90l x 95l x 100l x 105l x 110l x 115l x 140l CH QB32 5D (M) 100D (M) M10 x 100l x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 165l x 190l CHQB80 10D (M) 10D (M) 15D (M) 15D (M) 20D (M) 20D (M) 25D (M) 25D (M) 30D (M) 30D (M) 7 35D (M) 35D (M) 14.5 40D (M) 40D (M) 45D (M) 45D (M) 50D (M) 50D (M) 75D (M) 75D (M) x 165l 100D (M) 100D (M) M5 x 75l
CHQWB100 10D (M) CHQWB40 5D (M) 15D (M) 10D (M) 20D (M) 15D (M) 25D (M) 20D (M) 30D (M) 25D (M) 35D (M) 30D (M) 13.5 10 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) 100D (M) 75D (M) 100D (M) CH QWB50 10D (M) 15D (M) 20D (M) 25D (M) 30D (M) 35D (M) 12 40D (M) 45D (M) 50D (M) 75D (M) 100D (M) 38 Series CHQWB Construction CHQWB20 Rod end male thread CHQWB32 to CHQWB100 Rod
Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (standard) CQ2XB40-75D (microspeed cylinder) Front supply pressure: 0.025MPa Front supply pressure: 0.025MPa 686 686 Test cylinder Load converter 588 588 Theoretical thrust Theoretical thrust 490 490 Analyzing recorder Actual thrust Actual thrust 392 392 Thrust N Thrust N Pressure converter 294 294 196 196 Pressure
AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L
Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L
. + BQ Example) CDQ2B32-30DZ-BQ Surfaces with auto switch mounting slot A/B/C side except port side Surfaces with auto switch mounting slot Port side C A Auto switch mounting surface B qInsert the nut into the auto switch mounting slot on the cylinder tube, and place it in the roughly estimated setting position. wWith the lower tapered part of the auto switch spacer facing the outside of
Spacer-installed type 1 Standard model number CDQ2B32-57DZ-XC89 Uses a standard stroke (75 mm) tube. Makes 57 mm stroke with 18 mm spacer inside. The B dimension is 108 mm.
As the CDQ2B32-30DMZ-M9BW is a cylinder with 2 auto switches, be sure to order 2 D-M9BW auto switches if 2 are needed.
F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid
A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L
.: CQ2B50-57D 18 mm width spacer is installed in the standard CQ2B50-75D. B dimension is 115.5 mm. Part no. CQ2B50-57D-XB10 Makes 57 stroke tube. B dimension is 97.5 mm. Example Air-hydro type is excluded. In the case of spacer type, intermediate stroke with damper for 40 to 100, it can be manufactured by 5 mm intervals in 5 mm and 55 to 95 mm.
Example) 18 mm width spacer is installed in the standard cylinder 10CQ2XB40-75D to make 10CQ2XB40-57D. 12 16 20 25 Fluid Proof pressure Maximum operating pressure Minimum operating pressure Air 1.5 MPa 1.0 MPa Rod end thread Nil M Standard (Rod end female thread) Rod end male thread 0.04 MPa 0.035 MPa Without auto switch: 10 to 70C With auto switch: 10 to 60C 1 to 200 mm/s Ambient and fluid
Standard strokes (mm) Bore sizes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 32, 40 50, 63 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Example) For CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke CQ2XB40-75D cylinder. Specific Product Precautions Be sure to read before handling. Refer to pages 15 to 24 for safety instructions and precautions.
Example) For 10-CQ2XB40-57D, an 18mm spacer is installed inside a standard stroke 10-CQ2XB40-75D cylinder. Manufacturing intermediate strokes Intermediate strokes can be manufactured in 1mm increments by installing spacers in a standard stroke cylinder. The total length of the cylinder is the same as the longer standard stroke.