D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL 5 5 5 5.5 5.5 5 5 5 5.5 5.5 D-M9 type cannot be mounted on 25 and 40.
215 775 1200 470 (423 to 517) [Unit: mm] (Note) Model D H T E d W T D L Max.
E C x 200 (= D) 25 Note 1) Distance within which the table can move when it returns to origin.
-m For three phase 200 VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Three phase 200 to 230 VAC Single phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should
NCDQ8A(B)-(C)(M) (in) NCDQ8A(B)-100T(M) (025st to 100st) (in) D-A9, D-A9V Bore size D-M9(V), D-F9W(V) D-A9, D-A9V D-M9(V), D-F9W(V) D-F9BAL D-F9BAL Bore size A B HS A B HS A B HS A B HS A B HS A B HS 056 075 106 150 200 250 056 075 106 150 200 250 0.61 0.55 0.85 0.83 0.81 0.98 0.04 0.08 0.12 0.12 0.2 0.28 0.71 0.81 0.96 1.18 1.45 1.6 0.77 0.71 1 0.98 0.96 1.14 0.2 0.24 0.28 0.28 0.35 0.43
NCDQ8A(B)Z-(C)(M) (in) NCDQ8A(B)Z-T(M) (025st to 100st) (in) D-A9, D-A9V D-M9(V), D-M9W(V) D-A9, D-A9V D-M9(V), D-M9W(V) D-F9BAL D-F9BAL Bore size Bore size A B HS A B HS A B HS A B HS A B HS A B HS 056 075 106 150 200 250 300 400 056 075 106 150 200 250 0.24 0.14 0.33 0.31 0.2 0.35 0.37 0.49 0.04 0.08 0.12 0.12 0.2 0.28 0.34 0.53 0.71 0.81 0.96 1.18 1.45 1.6 1.94 2.44 0.39 0.3 0.49 0.47
/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B
E C x 200 (= D) 20 Note) When mounting the actuator using the body mounting reference plane, use a pin.
stroke end) and Mounting Height Proper Auto Switch Mounting Position (mm) D-Z7 D-Z80 D-Y59 D-Y69 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BAL Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AVL D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-A3 D-A44 D-G39 D-K39 D-A9 D-A9V D-A5 D-A6 D-A59W D-F5NTL D-P4DWL CJ1 CJP Bore size A A A A B A B B B B B B B B A A A A CJ2 32 40 50 63 80 100 125 6.5 4 10.5 8 0.5
(mm) Auto Switch Mounting Height D-A9l(V) D-M9l(V) D-M9lW(V) D-M9lA(V) D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 Auto switch model D-B5l D-B64 D-B59W D-G5NT D-H7C D-G39A D-K39A D-A3lA D-A44A D-C73C D-C80C Hs Hs Hs Hs Hs 20 24.5 25.5 25 60 69.5 25 27 28 27.5 62.5 72 32 30.5 31.5 31 66 75.5 40 34.5 35.5 35 70 79.5 Bore size D-X Technical Data 263 CM2 Series Auto Switch Proper Mounting Position
st 151 to 200 st D-M9l D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV 32 11.5 35.5 60.5 85.5 110.5 40 16.5 40.5 65.5 90.5 115.5 140.5 D-A9l D-A9lV 32 7.5 31.5 56.5 81.5 106.5 40 12.5 36.5 61.5 86.5 111.5 136.5 D-C7l/C80 D-C73C/C80C 32 8 32 57 82 107 40 13 37 62 87 112 137 D-A73 D-A80 32 8.5 32.5 57.5 82.5 107.5 40 13.5 37.5 62.5 87.5 112.5 137.5 D-A72/A7lH/A80H D-A73C/A80C D-F7l/F7lW D-J79/J79W
DZ/Y/YZ VFS3320-D/DZ/Y/YZ VFS3420-D/DZ/Y/YZ VFS3520-D/DZ/Y/YZ Lead wire O.D.
Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59A, D-Y69A D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B Auto switch model no.
There may be large variations depending on the surrounding environment (variations on the order of 30%). 66 Solid State Switches/Direct Mount/ D-Y59 /D-Y69 /D-Y7P(V) Series MGP Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
/C8 D-H7 A B 11.5 8.5 16 Auto switch D-C7/C8, D-H7 D-B5/B6 D-G5/K5 A 12 14.5 B 24.5 Auto switch D-B5/B6, D-G5/K5 D-B7/B8 D-G7/K7 8.5 A 14.5 B 11 Auto switch D-B7/B8, D-G7/K7 Auto Switch Mounting Position D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C Auto switch model D-C7/C8 D-C73C D-C80C D-G5 D-K5 D-G5NYL D-B59W D-H7 D-H7C D-H7W D-H79F D-H7BAL Bore size (mm
(A contact) D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL 0.5 0.5 0.5 0.5 0.5 3 3 3 3 3 Slide screw S Lead screw type N.C. (B contact) N.C. (B contact) Lead screw lead N.C. (B contact) N.C. (B contact) 6mm 12mm A B N.O. (A contact) N.O. (A contact) Stroke N.O. (A contact) 50mm 75mm 100mm 125mm 150mm 170mm 200mm 50 75 100 125 150 170 200 N.O.
A B Traveling accuracy (mm) Model D side against B side C side against A side LTF8 LTF6 0.02/200 or less 0.02/200 or less 0.02/200 or less 0.02/200 or less Simplified Selection Flow Chart Simplified Selection Flow Chart Simplified Selection Flow Chart Single Axis Electric Actuator Series LTF (AC Servomotor) Single Axis Electric Actuator Series LTF (AC Servomotor) Work load kg Maximum speed
Switch Internal Circuit D-Y7GL Motor model Compatible driver model Power supply voltage (VAC) Motor output (W) + Brown lead wire 100/115 200/230 100/115 200/230 100/115 200/230 MSD5A1P1E MSD5A3P1E MR-C10A1 MR-C10A SGDE-A5BP SGDE-A5AP Main circuit of switch Matsushita Electric Industrial Co., Ltd.
Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-M9E, D-M9EV (With indicator light) Auto switch model D-M9NE D-M9NEV D-M9PE D-M9PEV D-M9BE D-M9BEV Output signal turns on when no magnetic force is detected.