Auto Switch Proper Mounting Height [mm] Auto switch model D-B5l D-B64 D-B59W D-G5l D-K59 D-G5NT D-G5lW D-K59W D-G5BA D-G59F D-Z7l D-Z80 D-Y59l D-Y7P D-Y7BA D-Y7lW D-M9l D-M9lW D-M9lA D-A9l D-A3l D-G39 D-K39 D-A44 D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-M9lV D-M9lWV D-M9lAV D-A9lV Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Hs Hs Hs Ht 40 30 30 34 30 31 30 30 30
+ 55 (n 2) 2 (n = 2, 4, 6, 8)*1 25 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 D-A59W 1 15 25 2 (Different surfaces, same surface) 15 25 n (Same surface) 15 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 25 + 55 (n 2) 2 (n = 2, 4, 6, 8)*1 D-F5NT 1 10 25 D-Y59 D-Y7P D-Y7W D-Z7 D-Z80 2 (Different surfaces, same surface) 1 15 n 15 + 40 (n 2) 2 (n = 2, 4, 6, 8)*1 *1 When n is an odd number, an even number that is
Auto Switch Mounting Height (mm) Auto switch model D-A7H D-A80H/F7 D-J79/F7W D-F7BA D-J79W D-F79F D-F7NT D-M9V D-M9WV D-M9AV D-F7V D-F7WV D-F7BAV D-A7 D-A80 D-A73C D-A80C D-J79C D-A9V D-A79W D-P3DWA Bore size (mm) Hs Hs Hs Hs Hs Hs Hs Hs Hs 12 16 20 32 40 50 19.5 17 22.5 20 22 22.5 28.5 24.5 27.5 25.5 25 23 24.5 25.5 31 27.5 30 28 30 27.5 34 36 40.5 36.5 39.5 37.5 35.5 32 30 37.5 38 43.5
Auto Switch Proper Mounting Position (Detection at Stroke End) (mm) Auto Switch Mounting Height (mm) D-M9l D-M9lW D-M9lA D-A9l Hs 20 26.5 25 29 32 32.5 40 37 50 42.5 63 49.5 D-M9l D-M9lW D-M9lA D-A9l Auto switch model Auto switch model Bore size A B A B 20 12 24 8 20 25 11.5 24.5 7.5 20.5 32 13 25 9 21 40 18 27 14 23 50 20 32 16 28 63 18.5 33.5 14.5 29.5 Bore size Note) Adjust the auto switch
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V CHQ CHQ CHK 32 to 100 20 CHN Approx. U CHM 25 CHS CH2 Approx. U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.
-X 663 CE1 Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A9V D-M9V D-M9WV D-M9AV D-A9 D-M9 D-M9W D-M9A 12 to 20 25 U B A 32 to 63 D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV U D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-J7V D-F7BAV 12 to 20 U B A 32 to 63
A S G D L TG effective depth TL TF effective depth TL TD TB TC (mm) D (g6) DD (h9) AU A B BA BB BC BD BE BU F H J JA JB JJ K Size Rotation angle 20 30 40 90, 180 50 25 2.5 63 (11) 14 34 14.5 30.4 10 30 M8 x 1.25 11 6.5 3 90, 180 M5 x 0.8 depth 6 68 30 3 69 (11) 14 39 16.5 49 16 34.7 12 32 M10 x 1.5 14 8.5 4 90, 180 M6 x 1 depth 7 76 32 3 78 (13) 16 47 18.5 55 16 40.4 15 36 M10 x 1.5 14
) (n = 2, 4, 6) Note 3) D-H7 D-H7W D-H7BA D-H7NF (n 2) 2 70 + 45 (n 2) 25 + 45 70 25 10 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) D-C73C D-C80C D-H7C (n 2) 2 80 + 50 (n 2) 30 + 50 80 5 30 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) D-B5 D-B64 D-G5 D-K59 (n 2) 2 70 + 50 (n 2) 25 + 50 5 70 25 (n = 2, 3, 4, 5) (n = 2, 4, 6) Note 3) (n 2) 2 75 + 50 (n 2) 30 + 50 D-B59W 10 75 30 (n = 2, 3, 4,
Operating Range (mm) (mm) Auto switch model Bore size 20 25 32 40 Auto switch model Bore size 20 9 7 25 8.5 6 32 10 8 40 10.5 8 D-M9(V) D-M9W(V) D-M9A(V) D-H7/H7C D-H7W D-H7NF/H7BA D-G5/K59/G59F D-G5W/K59W D-G5BA/G5NT D-G39/K39 D-A9(V) D-C7/C80 D-C73C/C80C D-B5/B64 D-B59W D-A3/A44 4.5 6.5 4.5 6.5 8 10 9 10 4.5 5.5 5 5.5 8 13 9 10 13 10 9 14 10 10 14 11 5 5 5 5.5 Since this is a guideline
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-P3DW 13 11 11.5 10.5 11 12 D17 7 14.5 6 15.5 5.5 14 6 14 15.5 -X 397 MK Series Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height D-F79F/F7NT D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV B A U 20, 25 20, 25 U B A 32
Note 4) D-Z7 and D-Y types cannot be mounted. 25 to 63 (mm) Auto switch model D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA A B C D D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-Y7BA D-A9 D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-M9 D-M9W D-M9A D-A9 D-M9 D-M9W D-M9A D-A9 Bore size (mm) 25 32 40 50 63 19 23 18 98 94 99 42 38 43 75 79 74 22.5 26.5
Auto Switch Mounting Height (mm) D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G5BA D-G59F Auto switch model D-F5 D-J59 D-F5W D-J59W D-F5BA D-F59F D-F5NT D-Z7 D-Z80 D-Y59 D-Y7P D-Y7BA D-Y7W D-A9 D-M9 D-M9W D-M9A D-A3C D-G39C D-K39C D-A44C D-A9V D-M9V D-M9WV D-M9AV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size (mm) Ht Hs 40 50 63 80 100 Hw Hs Ht Hs Ht Hs Ht Hs
model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5 9.5 9 12 B 8 8.5 10.5 11.5 15.5 Hs 24.5 26 29 33 38.5 45.5 Hs Hs 22 24 26.5 30.5 36 43 A 7 6.5 8 10 9.5 12.5 20 25 32 40 50 63 20 25 32 40 50 63 32.5 35.5 39 44.5 51.5 Note) Adjust the auto switch after confirming the operating
6)*1 55 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mA 25 25 40 25 + 35 (n 2) 2 (n = 2, 4, 6)*1 60 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mV 25 25 35 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 35 + 35 (n 2) (n = 2, 3, 4, 5) D-M9mWV D-M9mAV 25 25 35 20 + 35 (n 2) 2 (n = 2, 4, 6)*1 35 + 35 (n 2) (n = 2, 3, 4, 5) *1 When n is an odd number, an even number that is one larger than the odd number is to be used for the
MY1 HT MY1 W MY1 W MY1CW (Cam follower guide type) 16, 20 25, 32, 40, 50, 63 MY2C MY2 H/HT MY3A MY3B MY3M B A B A Proper Auto Switch Mounting Position (mm) D-Z7/Z80 D-Y59/Y7P D-Y7W D-Y7BA D-M9V D-M9WV D-M9AV D-A9 D-Y69/Y7PV D-Y7WV D-M9 D-M9W D-M9A Bore size (mm) A B A B A B A B A B 16 20 25 32 40 50 63 74 86 70 90 94 106 90 110 102 118 102 118 97 123 97 123 132 148 132 148 127 153
Operating Range Auto Switch Mounting Bracket (Switch spacer) Auto switch model Bore size (mm) 6 to 40 Auto switch model Bore size (mm) 6 10 15 20 25 32 40 D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 3 3 2.5 2.5 3 2.5 3 BMY3-016 D-A9 D-A9V D-A9 D-A9V 5.5 5.5 5.5 5.5 5.5 5.5 6 Note) Values which include hysteresis are for guideline purposes only, they are not a
Auto Switch Mounting Height [mm] Operating Range Auto switch model Bore size D-M9V D-M9WV D-M9AV D-A9V [mm] Auto switch model Bore size 12 16 20 25 32 40 50 Hs Hs 12 19.7 17.2 16 21.5 19 20 23.2 20.7 25 24.7 22.2 32 29.5 27 40 31.2 28.7 50 34.5 32 D-M9/M9V D-M9W/M9WV D-M9A/M9AV 3.5 3.5 5 5 5.5 6 6 D-A9/A9V 7 9 9 9 9.5 9.5 9.5 Values which include hysteresis are for reference purposes only
(mm) D-M9V D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A90V D-A96V D-A93V Bore size (mm) D-A90 D-A96 D-A93 D-M9 D-M9W Bore size (mm) Mounting pattern q, w Mounting pattern e 32 32 20 22 35 20 10 15 25 12 5 10 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.