SMC Corporation of America
Elite Part Number Search
Search Results "CDM2RB25-100AZ"

This is a legacy product, and replaced byCDM2C20-100AZ-C73 CM2/CM3 ROUND BODY CYLINDER. CYL, RND BODY, AIR-CUSHION. ACTUATOR. 20MM CM2 DBL-ACT AUTO-SW. .94614 lb. HE.

This is a legacy product, and replaced byMGPM20TF-100AZ, CYL, GUIDE W/AIR CUSH,SLIDE BR, ACTUATOR, MGP COMPACT GUIDE CYLINDER, HM, 20MM MGP SLIDE BEARING, 3.34527 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040020MGPM20?0.67?0.750.830.911.171.371.571.761.962.162.633.033.423.82

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 125mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 175mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 250mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 250mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 175mm, Cushion: Rubber Bumper, Rod End Thread: Female Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in Magnet, Type: Pneumatic, Mounting Style: Front Mounting Style, Bore: 25mm, Stroke: 200mm, Cushion: Rubber Bumper, Rod End Thread: Female Rod End, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 70, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(m):

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length