SMC Corporation of America
Elite Part Number Search
Search Results "CDLSF125TN-700-A93L"

Dimensions/40 to 100 Basic/CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G D E H1 AL B1 K A N F N B C M S + Stroke H ZZ + Stroke (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10

Basic style: CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G RE A B REC CX D E CY H1 MQQ M AL B1 K A N F N B C M S + Stroke H RHC ZZ + Stroke MK(2) RS Q G (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

/My max. 0.3 Stroke (mm) Stroke (mm) 10 15 20 25 30 5 25 30 10 15 20 5 0.2 MXPJ6 3.5 2.6 2.3 1.4 MXP10 4.2 8.5 1.7 6.3 50 100 200 300 500 700 MXP12 9.8 17 13 4.5 Average speed Va mm/s Collision speed V mm/s MXP16 26 41 28 12 1 Nm = 0.7375 ftlbf Note) Average speed is used at static moment calculation. Collision speed is used at kinetic moment calulation.

L A93L 1 Air Slide Table Series MXQ Specifications 6 8 12 16 20 25 Cylinder bore size (mm) Port size M5 x 0.8 Rc 1/8 Air Fluid Double acting Action 0.15 to 0.7MPa Operating pressure 1.05MPa Proof pressure Ambient and fluid temperature 10 to 60C 50 to 500mm/s (Adjuster option/Metal stopper: 50 to 200mm/s) Operating speed range Rubber bumper (Standard, Adjuster option/Rubber stopper) Shock

state switch Yes Yes Grommet Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV M9P 3-wire (PNP) M9BV M9B 12 V Relay, PLC 2-wire 24 V Grommet F9NWV F9NW 3-wire (NPN) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) F9PWV F9PW 3-wire (PNP) 2-wire F9BWV F9BW 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV

switch 100V 12V Grommet With 3-wire (equivalent to NPN) 5V A96V A96 IC circuit F9NV F9N 3-wire (NPN) Relay PLC F9PV F9P 3-wire (PNP) F9BV F9B 2-wire Solid state switch 24V With Grommet Diagnosis indication (2-Color indicaiton) 12V F9NWV F9NW 3-wire (NPN) F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire PLC: Programable logic controller Lead wire length 0.5m " " (Example)A93 3 m " L " A93L

Lead wire length symbols: Auto switches marked with are made-to-order specification. 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Auto switches other than those listed above are also available. Refer to page 11-8-9 for details.

79.2 264 IN Minimum Stroke for Auto Switch Mounting (mm) Applicable auto switch model No. of auto switches mounted D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV 1 pc. 5 5 5 2 pcs. 10 5 10 Weight (g) Stroke (mm) Model 5 10 15 20 25 30 40 50 60 MXH6 MXH10 MXH16 MXH20 62 67 76 81 91 96 111 125 140 117 125 140 148 162 170 192 215 238 216 227 247 258 279 290 323 353 386 437 455 486 505 542 560 597 656 700

Magnet: D (Built-in), Mounting: F (Front Flange), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

F9BA * Lead wire length 0.5m (Example) A93 3m L (Example) A93L 5m Z (Example) F9NWZ * : Manufactured upon receipt of order. 2.2-2 Compact Cylinder/Standard: Double Acting Single Rod Series CQS Specifications Style Pneumatic (Non-lube) Action Double acting, single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Without auto switch 10C to 70C (No freezing) Ambient & fluid

A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire 24 V Relay, PLC 3-wire (NPN) 3-wire (PNP) Grommet 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 12V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L

Magnet: D (Built-in), Mounting: F (Front Flange), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: Z (5m Lead Wire)

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 5m Lead Wire, Number: -, Lock Unit Built-in Magnet: -, Lock

L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.