2 x FC Mounting hole B 0 0.3 A F NA FT NB FX FZ H S + Stroke F Z + Stroke Refer to page 148 for details of the mounting nut.
x L M F x L M F x L F F L L L 90 Mechanically Jointed Rodless Cylinder With Protective Cover Series MY1MW/CW How to Order MY1 M W 25 300 A93 Number of auto switches Guide type 2 pcs. 1 pc.
1 Stroke (mm) 100 50 0.05 0.1 0.5 1 2 3 0.1 0.05 0.5 1 2 5 Load (kN) Load (kN) 123 Hydraulic Cylinders: Technical Data 2 Series CHA Stroke range limit charts: Bore sizes 40, 50, 63, 80 Symbol Mounting orientation Mounting orientation Mounting orientation Mounting orientation Symbol Symbol Symbol F F F F F F F F F F F F Bore size 40 Bore size 50 3000 2 4 8 9 3 7 2 4 3 7 5 2000 8 9 1 5 1 6
CS1 series Without auto switch With auto switch H 120 120 130 145 145 175 190 Bore size (mm) F 50 50 50 55 55 69 69 ZZ 245 245 266.5 291 291 357.5 387.5 F 50 50 50 55 55 H 120 120 130 145 145 ZZ 245 245 266.5 295 300 125 140 160 180 200 250 300 F H ZZ + Stroke (mm) MB series Bore size H ZZ 32 47 135 40 58 146 50 67 165 63 67 165 80 81 199 100 81 199 ZZ + Stroke H (mm) MB1 series Bore
Long stroke Standard stroke Without auto switch With auto switch A Long stroke (mm) Standard stroke (mm) Bore (mm) C D E OA OB Q RA RB T H I K M N With/Without auto switch A L F 7.5 7.5 9 11 B 32 32 41 44 A L 3.5 3.5 4.5 5 B 22 22 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 B 17 17 F 5 5 5.5 5.5 12 16 20 25 45.5 13.5 25.5 5 to 30 5 to 30 5 to 50 5 to 50 35 to 100 35 to 100 75 to 200 75 to 300 6 8 7 12
(E X C E S S I V E F O R C E I N T H E D I R E C T I O N O F R O TAT I O N A P P L I E D T O T H E P I S T O N R O D M AY D A M A G E T H E I N T E R N A L M E C H A N I S M.) R E F E R T O T H E F O L L O W I N G TA B L E F O R D I M E N S I O N S W I T H A R M 32/40/50/63S E R I E S MK2 T I G H T E N I N G T O R Q U E F O R M O U N T I N G.
7.5 7.5 9 11 B 32 32 41 44 L 13.5 13.5 14.5 15 A 25.5 25.5 34 37.5 B 22 22 29.5 32.5 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 B 17 17 19.5 22.5 F 5 5 5.5 5.5 L 3.5 3.5 4.5 5 6 8 10 12 M4 x 0.7 25 29 36 40 6 8 7 12 6.5 6.5 9 9 7.5 7.5 9 11 7 7 10 10 4 4 7 7 0.5 0.5 1 1 M3 x 0.5 5 6 8 10 32 38 47 52 15.5 20 25.5 28 3.5 3.5 5.4 5.4 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M5 x 0.8 M6 x 1.0 M6 x 1.0 Note
(Excluding D-F9, F-9 V) Note 2) For solid state switches with flexible lead wire specification, add "-61" at the end of the lead wire length.
Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None Internal resistance 1 or less (including lead wire length of 3 m) D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.
D-A90V/D-A93V/D-A96V Note) 1. Operating load is an induction load. 2. The length of wiring to the load is 5 m or more. 3. The load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may be shortened. (Refer to page 12 for contact protection box.)
Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.
D-X Technical Data 321 CG1 Series Basic Spring return: CG1BN Width across flats KA Plug with fixed orifice GA F GB RcP MM H1 R0.4 D I E 0 0.05 E 0 0.05 C R0.4 H A AL TA K 4 x TC Width across flats B1 8 J ZZ + Stroke S + Stroke F TB NA C Spring extend: CG1BN Width across flats KA GB Plug with fixed orifice RcP GA F MM H1 R0.4 D I E 0 0.05 E 0 0.05 C R0.4 H + Stroke A AL K TA 4 x TC F TB Width
8 MY1HG-F (W) Component Parts Description Material Note No.
A A a B B s j C f g t C0.5 C0.2 C0.2 b d e 45 45 Section A-A p k C0.5 45 C n h i l (d) C0.5 q m O Section B-B r (l) View C (mm) +0.2 0 l i o j k m n p q r s t b e g a c d f h Model 0 0.2 0.05 0.15 + 0.1 0 +0.2 0 3.5 +0.013 +0.001 CXS 6 2.75 M2.5 x 0.45 4.5 3.5 4.75 C0.5 2.8 0.5 4 3.5 3 3.5 16 0.1 M3 x 0.5 4 1 5.5 6 +0.2 0 0.05 0.15 0 0.2 + 0.1 0 +0.2 0 5 +0.016 +0.001 CXS10 4 M3 x 0.5 8 5
) Black F 0V (power supply) (Shield) G Shield 3 High Precision Scale Cylinder Series CEP1 Construction 12, 20 !
Applicable model H G A B C J K E D F 16.5 MXS-AT6 5 MXS 6 7 10.5 2.5 21 19 8 5 M2.5 X 8 M5 X 0.8 MXS6, MXS8 26.5 MXS-AT6-X11 15 D 16.5 MXS-AT8 5 E E H MXS 8 M3 X 10 M6 X 1 8 12.5 3 25 9 6 22.5 26.5 MXS-AT8-X11 15 36.5 MXS-AT8-X12 25 5 G 20 MXS-AT12 MXS12 12 18.5 4 32 13 8 31 M4 X 8 M8 X 1 30 MXS-AT12-X11 15 B C 40 MXS-AT12-X12 25 24.5 MXS-AT16 5 F K K F A J MXS16 M5 X 10 M10 X 1 14 23 5 40
Model H G A B C J* K E D F 16.5 MXS-AT6 5 MXS 6 7 21 19 8 5 10.5 2.5 M2.5 X 8 M5 X 0.8 * MXS6, MXS8 26.5 MXS-AT6-X11 15 D 16.5 MXS-AT8 5 E E H MXS 8 M3 X 10 M6 X 1 8 25 9 6 12.5 3 22.5 26.5 MXS-AT8-X11 15 36.5 MXS-AT8-X12 25 5 G 20 MXS-AT12 MXS12 12 32 13 8 18.5 4 31 M4 X 8 M8 X 1 30 MXS-AT12-X11 15 B C 40 MXS-AT12-X12 25 24.5 MXS-AT16 5 F K K F A J MXS16 M5 X 10 M10 X 1 14 40 15 10 23 5
, D-A96, D-A96V (With indicator light) Precautions Caution D-A96, D-A96V D-A93, D-A93V Auto switch model Applicable load IC circuit Relay, PLC 24 VDC Load voltage 100 VAC 4 to 8 VDC Fix the auto switch with the existing screw installed on the auto switch body.
A90 A90V No Reed switch Solid state switch 2 wire 24V A93 A93V Grommet 100V 12V Yes 3 wire (NPN equiv.)