Extension locking F Retraction locking B CLJ2 CLM2 1 CLG1 Drop prevention Emergency stop CL1 A MLGC 2 B A CNG B MNB CNA A A CNS 3 B B CLS CLQ A RLQ A 4 B MLU B MLGP ML1C Mounting Caution 1. Be sure to connect the load to the rod end with the cylinder in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism. 2.
5 A B CL A CL1 MLGC B Extension locking Without magnet !0o#1 @8 t CNG MNB Section A-A' Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CNA !3 @0 CNS CLS Section B-B' (Both ends tapped) CLQ MLGP Retraction locking Section B-B' (Through-hole) !4 !7 !
B 1.8 1.6 Groove position of auto switch A 10.4 12.8 Model MHK2-12 MHK2-16 A B Dimensions A and B of other models are same as standard switch grooves.
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 D 8 10.5 13.5 16.5 32
DRail mounting Direct mounting 20D-A7H/A80H D-A73C/A80C D-F7BAL/F7BAVL D-F7/J79 D-F7V/J79C D-F7W/F79F D-F7WV D-J79W D-M9 D-M9V D-F9W D-F9WV D-F9BA D-A7/A80 D-A79W D-A9 D-A9V Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 3.5 6 9 12 A 6.5 10.5 8.5 11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32
D-M9N(V)/D-M9P(V)/D-M9B(V) Direct Mounting Style . D-F8N/D-F8P/D-F8B Direct Mounting Style . D-Y59A, B /D-Y69A, B /D-Y7P(V) Direct Mounting Style . D-F9G/D-F9H Normally Closed Direct Mounting Style. D-Y7G/D-Y7H Normally Closed Direct Mounting Style. 2-color Indication Type . D-F79W/D-F7PW/D-J79W Rail Mounting Style. D-F7NWV/D-F7BWV Rail Mounting Style .
(RS1H50 : 10mm RS1H63 : 15mm RS1H80 : 18mm) 1410 Heavy Duty Stopper Cylinder Series RSH/RS1H Auto Switch Proper Mounting Position (Detection at Stroke End) Auto switch B A Auto switch proper mounting position (mm) Auto switch models D-M9 D-M9W D-M9AVL RSQ D-M9V D-M9WV D-M9AL D-Z7/Z80 D-Y59/Y7P/Y7W D-Y69/Y7PV D-Y7WV D-Y7BAL RSG A B A B A B A B A B A B Bore size RS 20 32 50 63 80 23 8.5 23
Solid state switch D-F8 CUJ (As compared with SMC Series CU cylinders without magnet) Dimensions (Without magnet) Series Variations Bore size (mm) A(a) B(b) C(c) Bore size (mm) Rod end configuration Stroke (mm) Clean series 4 6 8 10 15 20 b Action Series Auto switch B Double acting Male thread Without thread None 4 10() 15() 13() 4 Single acting, Spring return 6 13(13) 19(22) 13(33) Double
CDQSWB125D 10D 15D 20D 25D 30D CDQSWB165D 10D 15D 20D 25D 30D CDQSWB205D 10D 15D 20D CDQSWB2025D 30D 35D 40D 45D 50D CDQSWB255D 10D 15D 20D 25D 30D 35D 40D 45D 50D 6.5 10 CU CQS CQ2 6.5 MU 7 10 Note) Appropriate plain washer must be used for through-hole mounting. 2.2-13 Compact Cylinder/Standard: Single Acting Spring Return/Extend Series CQS 12, 16, 20, 25 How to Order B 20 10 S CQS Standard
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V Approx.
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V Approx.
U B A Approx. U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.
U B A Approx. U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.
U A B B A D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U SMC SMC Approx. U B A B A Approx. U D-A73C D-A80C D-J79C D-A7*C,D-A80C Approx. U Approx. U D-A7*C,D-A80C A B A B Approx.
C D Flat Model A E K Model F H J F H J Flat with ribs ZPT40 -B-A14 U C ZPT40D10-B-A14 55 121.5 120 18.5 32 6.5 3.3 40 43 ZPT50 -B-A14 U C ZPT40D20-B-A14 127 65 124 50 19.5 33 7.5 3.8 50 53 137 5 10 6.2 13 ZPT40D30-B-A14 75 134 Dimensions by Stroke ZPT40D50-B-A14 182 95 179 75 1 8 E G: M5 x 0.8 G: Rc 40 50 H J F 40 50 H J F K Model 40 50 U C ZPT 20-B-A14 U C ZPT 30-B-A14 U C ZPT 50-B-A14 U
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9B,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9B,
B Bracket B Note) 1 Dimensions for mounting bracket B 2 Dimensions for mounting spacer B Spacer B is used to leave space for maintenance (for replacement of silencer etc.) on side mounting.