Manifold overall length Manifold overall length Approx. 29% reduced SY5000 manifold SY5000 3 stations SY3000 manifold SY3000 4 stations Mixed manifold SY5000 3 stations SY3000 4 stations For serial transmission EX260 A B A B A B A B A B A B A B A B A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 A B A 14 Installation space A A A A A A A A B B B B B B B B 12 B 12 B 12 B 12 B 12 B 12 B 136.7 mm
(Fluororubber seal) 12 MGP12-XC22-PS 16 MGP16-XC22-PS 20 MGP20-XC22-PS 25 MGP25-XC22-PS 32 MGP32-XC22-PS 40 MGP40-XC22-PS 50 MGP50-XC22-PS 63 MGP63-XC22-PS 80 MGP80-XC22-PS 100 MGP100-XC22-PS Grease Pack Part No. * Grease pack part numbers other than below are the same as basic type.
Magnet: Built-in, Mounting: Single Foot, Bore: 16mm, Stroke: 175mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper
Magnet: Built-in, Mounting: Single Foot, Bore: 16mm, Stroke: 175mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: Double Knuckle Joint, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Band Mounting, Cushion: Rubber Bumper, Series: J2
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
(Or None in the Case of No Switch), Auto Switch Mounting Type: B (Band Mounting)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9P, Lead
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 16mm, Stroke: 175mm, Cushion: Rubber Bumper, Head Cover Port: 90° to Axis, Auto Switch: Band Type Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Fluororubber Seals
MRQ L r b a = K + mL2 K: The moment of inertia around the center of gravity of the load K = m r2 12 a2 + b2 = m In case of 4. Round plate 2 4. Round plate (Including column) Position of rotational axis: Passing through the center axis 9. Gear transmission (A) (B) No. of teeth = a 1. Find the moment of inertia B for the rotation of shaft (B). 2.
CM3 Auto Switch Proper Mounting Position (Centralized piping type, With end lock) CG1 (mm) Auto switch model D-H7l D-H7C D-H7lW D-H7BA D-H7NF CG3 D-C7l D-C80 D-C73C D-C80C D-G39A D-K39A D-A3lA D-A44A D-M9l(V) D-M9lW(V) D-M9lA(V) D-A9l(V) D-G5NT D-B5l D-B64 D-B59W JMB MB A B A B A B A B A B A B A B A B Bore size MB1 20 10.5 (8) 9.5 (7) 6.5 (4) 5.5 (3) 0.5 () 0 () 6 (4) 5 (3) 2.5 (0.5) 1.5
Symbol -XC12 to XC21 CRB2 CRBU2 L L B B 10 CRB1 End of rotation Rotation starting point 10 Additional Reminders MSU A The rotation starting point is the position of the flat and the key groove when the actuator is pressurized through connection port B. There are no air cushion effects in the rotating ranges of 70 shown in the diagram.
A B B B A B A B A B A B A 20 25 32 40 6.5 5.5 10.5 9.5 1 0 6 4 3 0.5 0 6 5 2.5 1.5 7 6.5 5.5 10.5 9.5 1 0 6 4 3 0.5 0 6 5 2.5 1.5 7 7.5 6.5 11.5 10.5 2 1 7 5 4 1.5 0.5 7 6 3.5 2.5 8 13.5 11.5 17.5 15.5 7 6 12 10 9 6.5 5.5 12 11 8.5 7.5 13 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.