W CX U NA T NB Related Products L K F S + Stroke MA ZZ + Q + l + Stroke B Width across flats G RR SS + Stroke A ZZ + Stroke D(mm) With rod boot Stroke range (mm) Bore size (mm) J e CX B C F GA GB NA NB P R S T CD RR SS L U W l f Q B-rod C-rod B-rod C-rod 32 21.5 15 52 M10 x 1.25 25 to 1400 58 38 16 32 15 37 31 3/8 39 141 11 25 16 16 209 38 22 12.5 40 52 12 15 52 M10 x 1.25 25 to 1400 65
With air cushion 15 LH B 4 x LD Z Y X W LZ LX 2 x LC (Knock pin position) ZZ + S Stroke LS + Stroke Y X W M (mm) B 54.5 78 LS 54 LX 71 LZ 4 M 10 W 4 LC 7 LD 30 LH 3 LT 16.5 X 8.5 Y Z 63.5 205 ZZ Bore size 40 50 63 5 5 10 12 40 45 91 91 4.5 4.5 17.5 17.5 70.5 75.5 66 82 86 106 5 5 22 22 11 13 242 242 82.5 75.5 Other dimensions are the same as basic type.
Note) Applicable strokes are available in 5 mm increments. 249 Compact Hydraulic Cylinder Double Acting/Double Rod CHQWB Series 20, 32, 40, 50, 63, 80, 100 3.5 MPa How to Order B B 50 30 D CHQ CHDQ 50 30 M9BW D W W With Auto Switch With auto switch (built-in magnet) Number of auto switches Nil S n 2 pcs. 1 pc. n pcs.
Port side A, B, C Auto switch mounting rail side only q BQ-2 w BQ2-012 Two kinds of auto switch mounting brackets are used as a set. q BQ-1 w BQ2-012 Two kinds of auto switch mounting brackets are used as a set.
A B A B A B A B A B A B A B A B A B A B 40 10 8 6 4 4 1 5.5 3.5 3.5 0.5 0.5 0 1 0 7 4 2.5 0 4.5 1.5 12 9 50 10 8 6 4 3.5 1.5 5.5 3.5 3 1 0 0 0.5 0 6.5 4.5 2 0 4 2 11.5 9.5 63 12.5 11.5 8.5 7.5 6 5 8 7 5.5 4.5 2.5 1.5 3 2 9 8 4.5 3.5 6.5 5.5 14 13 80 16 14 12 10 9.5 7.5 11.5 9.5 9 7 6 4 6.5 4.5 12.5 10.5 8 6 10 8 17.5 15.5 100 17.5 16.5 13.5 12.5 11 10 13 12 10.5 9.5 7.5 6.5 8 7 14 13 9.5
MY1 HT MY1 W MY1 W MY1CW (Cam follower guide type) 16, 20 25, 32, 40, 50, 63 MY2C MY2 H/HT MY3A MY3B MY3M B A B A Proper Auto Switch Mounting Position (mm) D-Z7/Z80 D-Y59/Y7P D-Y7W D-Y7BA D-M9V D-M9WV D-M9AV D-A9 D-Y69/Y7PV D-Y7WV D-M9 D-M9W D-M9A Bore size (mm) A B A B A B A B A B 16 20 25 32 40 50 63 74 86 70 90 94 106 90 110 102 118 102 118 97 123 97 123 132 148 132 148 127 153
B Counter bore depth C T T Y HT HP P (Piping port) (Operating direction: A) L 0 -0.1 22 8 Note 1) TC X F 14 WP 19.5 12.5 D 30 13 WS GP GW 4 x LD PW QW Plug 12.5 P (Piping port) (Operating direction: B) 2 x 4 x MM Thread depth M Switch rail HR HS CR W K Plug G G Z + Stroke Q + Stroke CY3RG15 P (Piping port) (Operating direction: B) CY3RG25, 32, 40, 50, 63 Note 1) 50, 63: L 0 0.2 CY3RG10 B
MY-S25 MY-S32 MY-S40 Applicable cylinder A 105 130 145 B 119 148 167 C 35 45 55 D 50 64 80 E 8 11.7 14.8 F 5 6 8.5 G 9.5 11 14 H 5.5 6.6 9 J M6 x 1 M8 x 1.25 M10 x 1.5 A B A B A B MY1H25 MY1H32 MY1H40 MY1 HT Side supports consist of a set of right and left supports.
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
support A MY-SA 2 x G F 2 x H E C D A B Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.
a) b) D-M9 D-M9W D-M9A D-A9 D-M9V D-M9WV D-M9AV D-A9V MK MK MK2T CK1 CLK2 CLKG CKQ CLKQ Auto Switch Proper Mounting Position (mm) Auto Switch Mounting Height (mm) Auto switch model D-M9 D-M9W D-M9AV D-A9V D-M9V D-M9WV D-M9AV CK CLK D-M9A D-A9 D-A9V Bore size (mm) D-M9V D-M9WV CKQ Hs Hs Bore size A B W A B W A B W A B W 4.5 (2) 12 16 19 21 17 19 12 12 4 12 4 4 6 4 12 8 8 0 4.5 (2) 16 12
B 23.5 A 7.0 B A 10.5 (13.0) B Bore size 50 63 80 23.5 19.5 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values inside ( ) are for the D-A96/A96V.
D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30
Proper Mounting Position (Detection at Stroke End) and Mounting Height 32, 40, 50, 63 D-M9/D-M9W/D-A9 D-M9V/D-M9WV/D-A9V Hs B W A A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6)
+ Stroke K A + Stroke M G J W 16 Minimum lead wire bending radius 10 Auto switch Q F 4 x N through H thread effective depth C 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A B A B 12 5 to 30 19.5 16 23 19.5 6 6 23 4 21.5 M3 x 0.5 26 1.5 5 3.5
Allowable load mass on guides/Allowable moment w 3 Table 4.
V V V Detection combinations A V V B V V C V V Two auto switches Two positions of q, w and e can be detected. Pattern Step 1) Fully close the fingers. Step 1) Position fingers for gripping a workpiece. Step 1) Fully open the fingers.