Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: A93, Lead Wire
Magnet: Built-In, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 20mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 25mm, Stroke Adjust Symbol: None, Rod Boot: Nylon Tarpaulin, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -
Magnet: Built-In, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 20mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 25mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -
Magnet: Built-In, Mounting: Rear Trunnion, Style: Non-lube Air Cushion, Bore Size: 20mm, Thread: Rc (or M5 Depending on Style, Bore Size, and Thread Combinations), Piping: Screw-in Piping, Stroke: 50mm, Stroke Adjust Symbol: None, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, X Option: -
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: A93, Lead Wire
Magnet: Built-in Magnet, Mounting: Head Trunnion, Type: Air Cushion, Bore: 20mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 50mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewire Connection: 3m, Number: -, X Option
Magnet: D (Built-in), Type: Pneumatic, Mounting: B (Basic), Bore: 32mm, Port Thread: Rc, Stroke: 25mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: J (Nylon Tarpaulin), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: L (3m)
Magnet: Built-in Magnet, Mounting: Rod Flange, Bore: 40mm, Port Thread: Rc, Stroke: 25mm, Cushion: Rod Boot, Nylon Tarpaulin, Pivot Bracket: No Bracket, Rod End: No Bracket, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore: 40mm, Port Thread: Rc, Stroke: 25mm, Cushion: J (Rod Boot, Nylon Tarpaulin), Pivot Bracket: No Bracket, Rod End: No Bracket, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Type: Pneumatic, Mounting: Basic, Bore: 32mm, Port Thread: Rc, Stroke: 25mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: Nylon Tarpaulin, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Leadwire or Prewired Connector: 3m, Number: -
wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93 3mL A93L
Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV
Lead wire length symbols 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Refer to page 14 for additional details and applicable auto switches other than the above types.
Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L
L (Example) A93L 5m . Z (Example) F9NWZ Note 2) Solid state switches marked with a "" symbol are produced upon receipt of order. D-9 auto switch can also be mounted.
F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A93 (Example) A93L
This is a legacy product, and replaced byCDG1BH63-250Z-A93L, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, PE, 63MM CG DBL-ACT AUTO-SW, 6.11782 lb
This is a legacy product, and replaced byCDQ2A32-100DZ-A93L, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, 1.55172 lb