Magnet: Built-in, Mounting: Front Trunnion, Style: Aluminum Tube, Bore Size: 40mm, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Front Trunnion, Style: Aluminum Tube, Bore Size: 40mm, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 50mm, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 50mm, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Single Clevis, Style: Aluminum Tube, Bore Size: 50mm, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 40mm, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides, Auto Switch: B54L--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, 3M, Number: -, Lead Wire or Prewired Connector: -
This is a legacy product, and replaced byCDG1TN20-50Z-B54L, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, HE, 20MM CG DBL-ACT AUTO-SW, .88184 lb
Please contact us for the latest version.sales@ocaire.com, NCDME075-0400-B54L, ACTUATOR, NCM ROUND BODY CYLINDER, HE, .75 INCH NCM DBL-ACT AUTO-SW, .00000 lb
This is a legacy product, and replaced byCDM2L32-255Z-B54L CM2/CM3 ROUND BODY CYLINDER. CYL, RND BODY, DBL ACTING. ACTUATOR. 32MM CM2 DBL-ACT AUTO-SW. 2.49856 lb. LE.
WN V V V 1 A cable for the M12 connector is not included with the product. Refer to the Option on page 51 to order it separately. A grommet type is not available.
) Backup plate Special resin Guide roller B Special resin Guide roller A Stainless steel (80, 100) MX #6 Special resin (63 to 100) #7 #8 #9 MTS End cover Nickel plated (80, 100) y Carbon steel (80, 100) (80, 100) Wear ring Special resin u i o !
) Backup plate Special resin Guide roller B Special resin Guide roller A Stainless steel (80, 100) MX #6 Special resin (63 to 100) #7 #8 #9 MTS End cover Nickel plated (80, 100) y Carbon steel (80, 100) (80, 100) Wear ring Special resin u i o !
100) (80 and 100) (80 and 100) Black zinc chromated Seal list No.
+ A = 100 y, z + A 100 10 y, z + A = 200 y, z + A = 200 y, z + A = 300 y, z + A = 300 1 1 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 700 800 Stroke [mm] Stroke [mm] [Graph 6] Allowable load mass by stroke 32 [Graph 5] Allowable load mass by stroke 25 100 100 y, z + A = 0 y, z + A = 0 y, z + A = 50 y, z + A = 50 10 Load mass [kg] Load mass [kg] 10 y, z + A = 100 y, z + A = 100
Table 8-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L]
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: R (Front Lock), Release of Manual: N (Non-locking Type)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure