Rod side Flange Rod side flange: (F) Bore size (mm) Stroke range B FD FE FT FX FY FZ Fd 32 40 50 63 80 100 125 to 1400 79 90 110 120 153 178 216 57.5 32 36 45 50 63 75 102 64 72 90 100 126 150 180 7 9 9 9 12 14 14 7 20 to 700 to 800 to 1000 to 1000 to 1000 to 1000 50 55 70 80 100 120 138 3 3 2 2 4 4 10 10 12 12 16 16 25 31 38.5 39.5 45.5 54 Port Cushion valve 4-FD Fd FY B CJ1 Without Air
Note 4) The stroke range with rod boot is up to 1000 mm. Please consult with SMC when exceeding 1000 mm strokes.
IP67 (2) 1) Electrical entry: Connector type (A73C/A80C/C73C/C80C): 1000 VAC/min.
32 40 50 63 80 100 up to 700 25 79 32 64 10 3 7 50 C85 up to 800 31 90 36 72 10 3 9 55 up to 1000 38.5 110 45 90 12 2 9 70 Fd FY B CG1 up to 1000 39.5 120 50 100 12 2 9 80 up to 1000 45.5 153 63 126 16 4 12 100 up to 1000 54 178 75 150 16 4 14 120 FX FE FT MB FZ C95 Rear flange(G)/Locking at head end (Hl) Hl/ Rl Wl (mm) CA1 Cushion valve Stroke range Bore size (mm) ZZ ZZ FZ FY FX FT FD B
Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 1000mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type)
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 50mm, Stroke: 1000mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
(Nil) u Auto switch mounting bracket Example Rail mounting CDBJ2B16-45-HN-A Band mounting CDBJ2B16-60-HN-B Nil 2 pcs. S 1 pc. n n pcs. : For rail mounting, screws and nuts for 2 auto switches come with the rail. : Refer to page 148 for auto switch mounting brackets. Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.
Rubber bumper50 to 750 mm/s (Standard equipment) Air cushion50 to 1000 mm/s The installation is simple because a tool can be placed directly over the cover for installation. The bearing portions of the rod cover and the clevis have been improved in wear resistance to ensure the longevity of the cylinder.
Up to 600 Up to 1000 Up to 600 Up to 1000 Up to 750 Up to 1000 Up to 750 Note) End boss is machined on the flange for E.
Up to 600 Up to 1000 Up to 600 CA2 Up to 1000 Up to 750 Up to 1000 Up to 750 CS1 Note) End boss is machined on the flange for E.
JMB MB MO WL RF WL C0.1 MB1 CA2 NA C0.1 KA CS1 8 x J CS2 (mm) Bore size (mm) Stroke range A AL B1 C D DL2 E F GA GB H H1 HR HN (Max.)
, NPT, G) Width across flats KA J DL DL RF MO DL MM HR E D E HN Air-hydro CA2H Air-hydro CA2WH Auto switch Made to order Precautions H1 AL Width across flats B1 Width across flats of hexagon hole WB 2-cushion valve A N F K N B C M H S + Stroke ZZ + Stroke With rod boot e 9 l f h + l ZZ + l + Stroke (mm) HN Stroke range Bore size (mm) B C (MAX) P A AL B1 D DL E F G H H1 HR J K KA M MM MO N
4 x N through I HR D 1 E M End Lock Mechanism Dimensions (mm) Flat washer HN (Max.)
HR MO RF WL WL KA 0.1 C 8-J NA (mm) Stroke range Bore size (mm) A AL B1 C D DL2 E F GA GB H H1 HR HN (max.)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 1000mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Air Cushion, Bore Size: 50mm, Stroke: 1000mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting
Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type)
Magnet: D (Built-in), Mounting: B (Basic Style), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 125mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type)