size 2-G 3 4 Electrical entry 6-Rc 1 4 2-Rc 1 8 Pilot EXH port 1(P), 3(R2), 5(R1) port Insert plug with lead wire Lead wire length L = 1000 Indicator light Push type manual override 150.5 (Double) 101 (Single) 158 (3 position) 2-Rc 1 8 External pilot port Stations Bottom ported: VV5FS2-01W2-01 Station U side D side 2n-Rc , 1 8 1 4 2(B), 4(A) port 2n-Rc 1 8 n: Stations Stations Formula L1 = 25n
size 2-G 3 4 Electrical entry 6-Rc 1 4 2-Rc 1 8 Pilot EXH port 1(P), 3(R2), 5(R1) port Insert plug with lead wire Lead wire length L = 1000 Indicator light Push type manual override 150.5 (Double) 101 (Single) 158 (3 position) 2-Rc 1 8 External pilot port Stations Bottom ported: VV5FS2-01W2-01 Station U side D side 2n-Rc , 1 8 1 4 2(B), 4(A) port 2n-Rc 1 8 n: Stations Stations Formula L1 = 25n
(Tensile strength is approx. 25N when being inserted 8mm.) Consult SMC if you intend to use with fluids other than air, noncorrosive gas and non-inflammable gas. 1. Do not drop, bump, or apply excessive impact while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2.
wire length L = 1000 Indicator light Push type manual override 158 (3 position) 150.5 (Double) 101 (Single) External pilot port Station Bottom ported: VV5FS2-01W2-01 Stations U side D side 2(B), 4(A) port n: Stations 1 70 81 2 95 106 3 120 131 4 145 156 5 170 181 6 195 206 7 220 231 8 245 256 9 270 281 10 11 12 13 14 15 295 306 320 331 345 356 370 381 395 406 420 431 Stations Formula L1 = 25n
(Tensile strength is approximate 25N at 8 mm inserted.) -5No.PS-OMG0009-D Wiring Do not pull the lead wires. In particular, never lift a Pressure Sensor equipped with fitting and piping by holding the lead wires. Avoid repeatedly bending or stretching the lead wire, or placing heavy load on them.
The tensile strength of the power supply/output connection cable is 50N and the sensor lead wire with a connector is 25N. Applying a greater pulling force than the applicable specified tensile strength to either of these components can lead to a malfunction. When handling, hold the body of the controller. 20 mm or more Cable wire color Connector no.
Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: TN (NPT), Stroke: 150mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: N (Non-locking Type), Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: TN (NPT), Stroke: 50mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: N (Non-locking Type), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: L (Axial Foot), Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: TN (NPT), Stroke: 50mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: R (Front Lock), Release Type: N (Non-locking Type), Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread
Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: NPT, Stroke: 150mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Non-locking Type, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: NPT, Stroke: 50mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Non-locking Type, Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Power and output lead wire: 50N or less Lead wire with connector for sensor: 25N or less Hold the body when handling to avoid the damage of the Controller which lead to cause the failure and malfunction. Do not insert metal wires or other foreign matter into the pressure measurement port. It can damage the pressure sensor causing failure or malfunction.
-2No.PS-OMH0005CN-D 1 1.5 3) *3) 1 1 () -3No.PS-OMH0005CN-D () () -4No.PS-OMH0005CN-D ( ) * (10 10 ) * (13 ) FG (50N 25N ) -5No.PS-OMH0005CN-D *() 6 33 2 () () 10m DC(-)() * ( ) ( ) CE -6No.PS-OMH0005CN-D -5~50 * ON , 20~30 1% 18~27 LCD * -7No.PS-OMH0005CN-D PSE20 2 0 NPN5 + 1 PNP5 + 4C (4 ) 1 A B + 1 M SI 2 1 2 kPa MPa / ZS-26-A 2 m ZS-28-C 1 ZS-26-B (M38L 2
Tensile strength of each lead wire Cable type Tensile strength Connector Assembly (for solenoid valve) 25N or less Lead wire with connector for pressure switch for vacuum 35N or less Lead wire with connector for pressure switch with energy saving function 20N or less Pressure sensor assembly 50N or less -6No.
Tensile strength of each lead wire Cable type Tensile strength Connector Assembly (for solenoid valve) 25N or less Lead wire with connector for pressure switch for vacuum 35N or less Lead wire with connector for pressure switch with energy saving function 20N or less Pressure sensor assembly 50N or less -7No.
11 63.6 33.6 0.05 102.7 2-M6 x 1 thread depth 12 (Mounting thread) M5 x 0.8 (Finger closing port) 4-M5 x 0.8 (Thread for mounting attachment) M5 x 0.8 (Finger opening port) 20 Auto Switch Mounting Groove Dimensions 12 0 0.05 6 12 6.2 10.7 Auto switch mounting groove 5 23.5 (For D-Y) For single action, the port on one side is a breathing hole. 4 11.5 Finger Position/Narrow Type 19 MHZ2-25N
11 63.6 33.6 0.05 102.7 2-M6 x 1 thread depth 12 (Mounting thread) M5 x 0.8 (Finger closing port) 4-M5 x 0.8 (Thread for mounting attachment) M5 x 0.8 (Finger opening port) 20 Auto Switch Mounting Groove Dimensions 12 0 0.05 6 12 6.2 10.7 Auto switch mounting groove 5 23.5 (For D-Y) For single action, the port on one side is a breathing hole. 4 11.5 Finger Position/Narrow Type 19 MHZ2-25N