SMC Corporation of America
Elite Part Number Search
Search Results "CDA2BQ40-50F-A54L"

Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.

-25A VND50D-32A VND50D-32F VND60D-40A VND60D-40F VND70D-50A VND70D-50F 1 8 1 4 26 28 31 120 130 240 380 7 0.3 3 8 15 0.6 1 2 3 4 20 0.9 1.4 2.3 5.5 3.6 7.2 5.7 10.8 25 1 VC 1 4 1 440 32 32 1 2 1 VDW 920 40 40 2 VQ 1500 50 50 Note) The companion flange is JIS B 2210 10K (standard) or its equivalent.

For Use in North, Central and South America Refrigerated Air Dryer (UL, CSA Standards) Applicable for the high-temperature environments Ambient temperature : Max. 113F (45C) Inlet air temperature : Max. 149F (65C) Air flow capacity * IDFB90-23, Dew point of 50F (10C) 459 SCFM (780 m3/h) (13% increase compared to the current model) Power supply voltage Single-phase 230 VAC (60 Hz) Single-phase

N.C. 6A 8A 10A 10A 15A 20A 25A 32A 32F 40A 40F 50A 50F 1 8 1 4 3 8 3 8 1 2 3 4 7 1 15 2 20 3 25 4 1 1 1 4 32 5 11 4 B Flange 11 2 40 6 11 2 B Flange 2 50 7 2B Flange 634 Steam Valve: 2 Port Valve For SteamVND Series Model Port size Flow rate characteristics Weight (kg) Orifice dia.

VNC7-50F 7 770 520 770 520 500 330 500 330 320 210 320 210 220 130 140 90 90 55 70 45 23 18 0.2 0.3 3/8 0.5 0.7 1/2 0.8 1.0 3/4 1.2 1.4 1 1 1/4 2.2 2.4 5.0 5.2 32 1 1/2 3.6 3.8 6.8 7.0 40 Symbols 5.5 5.7 2 Valve type Operation N.C.

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Besides the above models, there are some other auto switches that are applicable.

(Example) A54 (Example) A54L (Example) A54Z Since there are other applicable auto switches than listed, refer to page 10-15-76 for details.

Lead wire length symbols: 0.5 mNil 3 m L 5 m Z (Example) A54 (Example) A54L (Example) A54Z Since there are other applicable auto switches than listed, refer to page 10-15-76 for details.

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Since there are other applicable auto switches than listed, refer to page 6-9-30 for details.

Terminal conduit 12 V Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 24 V Grommet 2-wire 12 V Water resistant (2-color indication) With diagnostic output (2-color indication) Latch type with diagnostic output (2-color indication) 5 V, 12 V IC circuit 4-wire (NPN) P5DW Lead wire length symbols: 0.5 mNil (Example) A54 3 m L (Example) A54L

80, 100 125, 160, 200, 250 320, 400, 500 ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available MODEL TYPE LOAD VOLTAGE LOAD CURRENT POWER SOURCE INTERNAL VOLTAGE INDICATOR LAMP R O D T Y P E D-A53L REED 24VDC 5~50mA 2.4V or less ON:Red L.E.D Single Rod W Through Rod 24VDC 100VAC 200VAC 5~50mA 5~25mA 5~12.5mA A I R C U S H I O N 2.4V or less ON:Red L.E.D D-A54L

D-A80CL Reed 24VDC/AC or less 100VDC/AC Max 50mA Max 20mA None Diameter 30mm D-F79L ~ 3 Wire Solid State NPN 28VDC or less Max 150mA 5~28VDC 0.8V Max ON:RED L.E.D D-F7PL ~ 3 Wire Solid State PNP 28VDC or less Max 100mA 5~28VDC 0.8V Max ON:RED L.E.D D-J79L D-J79CL 2 Wire Solid State 28VDC or less 5~150mA ~ 3V Max ON:RED L.E.D D-A53L Reed 24VDC 100VAC 5~50mA 2.4V or less ON:Red L.E.D 3m D-A54L

Lead wire length symbols: 0.5 mNil (Example) A54 3 mL (Example) A54L 5 mZ (Example) A54Z Since there are other applicable auto switches than listed, refer to page 9-7-26 for details.

Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z In addition to the models in the above table, there are some other auto switches that are applicable.

Lead wire length symbols: 0.5 mNil (Example) A54 3 mL (Example) A54L 5 mZ (Example) A54Z Since there are other applicable auto switches than listed, refer to page 9-7-26 for details.

Terminal conduit 12 V Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 24 V Grommet 2-wire 12 V Water resistant (2-color indication) With diagnostic output (2-color indication) Latch type with diagnostic output (2-color indication) 5 V, 12 V IC circuit 4-wire (NPN) P5DW Lead wire length symbols: 0.5 mNil (Example) A54 3 m L (Example) A54L

10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz Valve size 1 7 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1 1 1 4 32 (22) 5 1 B 1 4 Flange 32F Nil: Non-locking push type 40A 1 1 2 Valve size 2 to 9 40 (28) 6 1 B 1 2 Flange 40F 2 50A 50 (33) 7 50F

C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?phase 200 VAC (50/60 Hz)2.1 A5 A180/200 W 50/60 Hz220 W0.01 ?m (99.9% filtration efficiency)Particles of 0.3 ?

C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?phase 230 VAC (50/60 Hz)4.8 A10 A385/440 W 50/60 Hz420 W0.01 ?m (99.9% filtration efficiency)Particles of 0.3 ?

C)50F (10?C)?0.18F (?0.1?C)?0.9F (?0.5?C) (including accuracy of the sensor)Single?phase 100 VAC (50/60 Hz)4.2 A10 A180/200 W 50/60 Hz220 W0.01 ?m (99.9% filtration efficiency)Particles of 0.3 ?