SMC Corporation of America
Elite Part Number Search
Search Results "CC100-100L12-5C"

Nominal Size: 100mm, Stroke: 600mm, Size: L (High Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 1 (Stop Valve/Skip Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)

Nominal Size: 100mm, Stroke: 200mm, Size: L (High Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)

Nominal Size: 100mm, Stroke: 200mm, Size: L (High Flow Style), Control Valve: 1 (Speed Controller), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)

Nominal Size: 100mm, Stroke: 500mm, Size: L (High Flow Style), Control Valve: 1 (Speed Controller), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)

Nominal Size: 100mm, Stroke: 200mm, Size: L (High Flow Style), Control Valve: 1 (Speed Controller), Combination Valve: 1 (Stop Valve/Skip Valve), Voltage: 5 (24VDC), Electrical Entry: C (Conduit)

Nominal Size: 100mm, Stroke: 200mm, Size: Small Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 200mm, Size: High Flow Style, Control Valve: None, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 300mm, Size: High Flow Style, Control Valve: Metering Valve, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 300mm, Size: Small Flow Style, Control Valve: Metering Valve, Combination Valve: Skip Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 400mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 600mm, Size: High Flow Style, Control Valve: Metering Valve, Combination Valve: Stop Valve/Skip Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 200mm, Size: High Flow Style, Control Valve: Metering Valve, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 200mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 500mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve, Voltage: 24VDC, Electrical Entry: Conduit

Nominal Size: 100mm, Stroke: 200mm, Size: High Flow Style, Control Valve: Speed Controller, Combination Valve: Stop Valve/Skip Valve, Voltage: 24VDC, Electrical Entry: Conduit

OFF 1 5C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value.

OFF 1 5C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value.

Data Maximum Settable Temperature Graph 1: IDH4 Graph 2: IDH6 F 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) 50F (10C) 44.6F (7C) 41F (5C) Pressure dew point 37.4F (3C) Air flow capacity scfm (L/min [ANR]) 17.6 (500) 28.3 (800) Air flow capacity scfm (L/min [ANR]) 15.9 (450) Selection example 24.7 (700) 14.1 (400) 21.2 (600) 12.4 (350) Selection example Selection example 10.6

Water 15% Ethylene Glycol Aqueous Solution Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Physical property value Temperature Density [kg/L] Specific heat C [J/(kgK)] Current unit system Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 Weight volume ratio [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.02

Pump automatic running and stopping is repeated to prevent freezing by maintaining circulating fluid temperature at 3C to 5C. Pump automatically starts operating if the circulating fluid temperature drops below 3C. Circulating fluid is heated by the pump power generated by pump operation.