SMC Corporation of America
Elite Part Number Search
Search Results "AV5000-F10-5DZC-A"

(A-B)/4 n_1=B+(A-B)/4 A= H_1= (A-B)/2 H_1= (A-B)/2 B= OUT2P_1n_1H_1P_2n_2H_2 -33No.PS-OMM0002CN-F [F 9] 30 () <> [F 9] [Eco] [F9] 30 (ON ) ON -34No.PS-OMM0002CN-F [F10] <> [F10] [Pin] [F10] 000 40 -35No.PS-OMM0002CN-F [F98] <> [F98] [ALL] [on] 1 [oFF] [oFF] 2 [F98] 1 37 -36No.PS-OMM0002CN-F 1 2 OUT1 3 OUT1 4 OUT1 5 OUT1 6 7 OUT2 8 OUT2 -N-P 9 OUT2

() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3 36.3 N7 1/4 10.3 8.3 PFM7-01/02--X694 PFM7S-01/02--X694 A B C() A B C() Rc1/81/4 Rc1/81/4

Description Material AV2000-A AV3000-A AV4000-A AV5000-A 4 Pilot valve assembly*1 See below.

kPa220 kPa (ON/OFF) OFF ON (43 ) 1 5 2 OUT1 OUT2 / (62 ) (48 ) (45 ) ,[F10](56 ) -42No.PS-OMT0001CN-E 4 () (ON/OFF) () (45 )OUT1

DCVX2 (2 )VX2 -37No.PS-OMR0001CN-J 3 ISA-19ISA-12ZS-31-B ISA-16ZS-31-C ISA-15 ISA-20 2.6 ISA-14 -38No.PS-OMR0001CN-J 3 () ISA-19ISA-12ZS-31-B ISA-16ZS-31-C ISA-15 ISA-20 ISA-20 E210-U01 2 ISA-17 2.6 2.6 Y200T-A -39No.PS-OMR0001CN-J 3 () 2 2 E210-U01 ZS-31-C ZS-31-C ZS-31-B Y200T-A Y200T-A ISA-18 2.6 ISA-15 ISA-16ISA-17 ISA-12-40No.PS-OMR0001CN-J 4 80 kPa220 kPa

CAT.ES40-39 B Soft Start-up Valve A V2000/3000/4000/5000 New New Series AV5000 introduced!

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Push-turn Locking Lever Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 12 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 24 VDC, Lead Wire: Type D, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Push-turn Locking Slotted Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: G, Port Size: 1, Option: None, Voltage: 24 VDC, Lead Wire: M12 Connector, w/o Cable, Surge Suppressor: with Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: YO (Type Y DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: YO (Type Y DIN Terminal w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: D (Type D, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right

Body Size: 5000, Thread: F (G), Port Size: 10 (1), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Flow Direction/Pressure Unit: Flow Direction: Left to Right