SMC Corporation of America
Elite Part Number Search
Search Results "ASB2201-G01-06H"

(Request)[STX] 01WSV100258 [ETX] [5Ch] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message SV1 Circulating fluid set temperature [06h] BCC value 00258 Write information (25.8 oC) [5Ch] BCC value 5.8 Command explanation HRS Series 5-18 HRX-OM-M091 Chapter

(Request)[STX] 01WSV100258 [ETX] [5Ch] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message SV1 Circulating fluid set temperature [06h] BCC value 00258 Write information (25.8 oC) [5Ch] BCC value 5.8 Command explanation HRSH Series 5-18 HRX-OM-Q033 Chapter

(Response)STX01ACK][ETX][06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message STR Saves data [06h] BCC value [02h] BCC value HRS100/150 Series 5.8 Command explanation 5-21 HRX-OM-S010 Chapter 5 Simple communication protocol function 5.9 Negative response If the request is not normal when

ALM_CLR Byte Description Command Response Phases in which the command can be executed Synchronization classification Asynchronous command 1 06H 06H Phase 2 and 3 2 See (2) ALM_CLR_MO D Specifications. Processing time ALARM Subcommand Cannot be used 3 Clears the followings.

Acknowledge code ACK 06H 3-8 HEF002-A6 Communication Format 3.8 Connection (RS-485) A terminal resistance needs to be mounted on the master and slave that are placed the furthest from each other.

Acknowledge code ACK 06H 3-8 INR-244-831 Communication Format 3.8 Connection A terminal resistance needs to be mounted on the master and slave that are placed the furthest from each other.

Acknowledge code ACK 06H 7.4 Communication 7-17 A_HEC-OM-J004-4 Chapter 7 Appendix 7.4.10 Connection (for RS-485) A terminal resistance needs to be mounted on the master and slave that are placed the furthest from each other.

KK130P-06H -08H -10H -12H -07H -09H -11H -13H KK130S-06H -08H -10H -12H -07H -09H -11H -13H 6 6 Metric size mm Inch size Metric size mm Inch size 8 8 10 10 12 12 1/4" 1/4" 5/16" 5/16" 3/8" 3/8" 1/2" 1/2" Refer to the how to order on page 1 for the sleeve lock mechanism provided type.

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 06 (ø6), Seal Method: without Sealant, Option: BH [for Welding Environments, Brass Parts (External), No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 06 (ø6)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: w/o Sealant, Option: B (None)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 06 (ø6), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 06 (ø6), Seal Method: Without Sealant, Option: BD (Welding Environment, Brass Parts, No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: BD (Welding Environment, Brass Parts, No Plating)

Body Size: 2 (1/8, 1/4), Control Type: 0 (Meter-out), Thread Type: G (G), Port Size: 01 (1/8), Applicable Tubing O.D.: 08 (ø8), Seal Method: Without Sealant, Option: D (General Environment, Brass Parts, Ni Plating)

Body Size: 1/8, 1/4, Control Type: Meter-out, Thread Type: G, Port Size: 1/8, Applicable Tubing O.D.: ø6, Seal Method: -, Option: -, Lock Nut Option: -

Body Size: 1/8, 1/4, Control Type: Meter-out, Thread Type: G, Port Size: 1/8, Applicable Tubing O.D.: ø8, Seal Method: w/o Sealant, Option: None, Lock Nut Option: -

Body Size: 1/8, 1/4, Control Type: Meter-out, Thread Type: G, Port Size: 1/8, Applicable Tubing O.D.: ø8, Seal Method: -, Option: -, Lock Nut Option: -

Body Size: 1/8, 1/4, Control Type: Meter-out, Thread Type: G, Port Size: 1/8, Applicable Tubing O.D.: ø6, Seal Method: Without Sealant, Option: General Environment, Brass Parts, Ni Plating