03 04 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: 3/8 04: 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Individual EXH spacer 179 (plug-in type) 133 (plug lead type) VVQ5000-R-1T (Plug-in type) VVQ5000-R-5T (Plug lead type) 03 04 03 04 32 16 By mounting individual
AS320-03-SD Rc 3/8 19 22.5 R 3/8 24.3 9.8 30 52.6 19.7 1.2 47.4 128 AS420-N04-SD NPT 1/2 23.8 NPT 1/2 AS420-F04-SD G 1/2 AS420-04-SD Rc 1/2 24 27.5 R 1/2 28.5 12.4 38.5 62.9 25.8 1.2 55.8 222 Reference thread dimensions after installation. 751
Rc 3/8 19 R 3/8 22.5 24.3 9.8 30 53.7 20.8 1.2 47.4 AS420-N04-SD NPT 1/2 23.8 NPT 1/2 AS420-F04-SD G 1/2 AS420-04-SD Rc 1/2 24 R 1/2 12.4 38.5 27.5 28.5 63.8 26.7 1.2 55.8 Reference thread dimensions after installation. 15-9-91
How to Order Sub-plates 04 P VQ5000 Electrical entry Port size Replacement of pilot valve assembly (Voltage) Refer to pages 2-6-40 to 2-6-41 for pilot valve assembly part numbers. Refer to page 2-6-3 for replacement method. 04 Rc 1/2 Porting specifications P S Plug-in conduit terminal Plug lead Note1) For bottom ported, port size is Rc 1/2.
If it is not connected to the SD terminal, normal transmission is impossibile even for a short distance.
Type: Speed Controller, Body Material: [Brass] Brass + Electroless Nickel Plating, Control Method: Meter-Out, Flow Rate(l/min): 1,700, Format: [Elbows] Cylinder direct-connected elbow type, Environment, Applications: Standard, Ambient Temperature and Working Fluid Temperature(°C): -5~60, Thread Portion Material: [Brass] Brass + Electroless Nickel Plating, Operating Pressure Range(MPa): 0.1
Type: Speed Controller, Body Material: [Brass] Brass + Electroless Nickel Plating, Control Method: Meter-Out, Flow Rate(l/min): 1,700, Format: [Elbows] Cylinder direct-connected elbow type, Environment, Applications: Standard, Ambient Temperature and Working Fluid Temperature(°C): -5~60, Thread Portion Material: [Brass] Brass + Electroless Nickel Plating, Operating Pressure Range(MPa): 0.1
Body Size: 4 (1/2 Basis), Control Method: 0 (Meter-out), Thread: F [G(PF)], Port Size: 04 (1/2), Sealant: S (Sealant)
Body Size: 4 (1/2 Basis), Control Method: 0 (Meter-out), Thread: N (NPT), Port Size: 04 (1/2), Sealant: S (Sealant)
DB:() SD: 3. [Pr. PA04]SD[Pr.
Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01-06-X214 Operation 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Caution
P = 11.5 1 2 3 4 5 6 7 8 ... n: Stations 40.5 Silencer cover L Blanking plug (for One-touch fitting) Dimensions Applicable fitting size d 3.2 4 6 8 A 23 04 06 08 Model A L D KQ2PKQ2P-23 KQ2P-04 KQ2P-06 KQ2P-08 16 16 18 20.5 31.5 32 35 39 3.2 6 8 10 This is inserted into cylinder ports and SUP and EXH ports that are not used.
UL/C-ULK5 13 19 13 13.6 (1) (a) () SD 1(4.12) (b) ( ) (c) () 13 20 13 M 1. 2. 3. () 4. 5. 1. 2. 3. () 4. 1. ()(FR-BIF()) 2.
FG SD FG SD FG SD FG CANL Twisted pair wire with shield FG BDL Class 3 ground Class 3 ground Class 3 ground Class 3 ground CANH V+ Connect the shielding wire to the SD terminal.
VFS VS Blank plug (For One-touch fittings) Dimensions (mm) VS7 23 04 06 08 Color: White KQP-X19 X19 A L D Model Fittings size d 16 16 18 20.5 3.2 6 8 10 31.5 32 35 39 KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 3.2 4 6 8 It is inserted into an unused cylinder port and SUP/ EXH ports. The minimum order quantity is 10 pcs.
If the shielding wire is not connected to the SD terminal, normal transmission will be impossible even for short distances. Furthermore, do not ground the shielding wire (SD).
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Do not connect any wire to other PIN numbers. Fig. 3-9 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Do not connect any wire to other PIN numbers. Fig. 3-9 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Fig. 3-10 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.
Terminal resistance 1 1 1 9 5 9 5 9 5 SDSD+ SDSG SD+ SD+ SD+ SG SDSG SDSG Terminal resistance120 Master This product This product This product (first slave) second slave 31st slaves Do not connect any wire to other PIN numbers. Fig. 3-10 Connection of RS-485 Tips Both ends of the communication connection (the end nodes) need to be connected to the host computer.