For AC2040 For AC3040 For AC4040 For AC4040-06 Model Description 02 03 04 06 E50-06 E3002 03 04 E2001 02 03 E40Piping adapter Attachment Accessory 4 4 4 06 4 VHS201 02 02 03 VHS3000VHS402 03 04 Y24-01 02 02 Y34-01 Y44-02 03 Y54-03 04 02 03 04 2 2 2 Y IS1000E02 03 04 3 3 3 Y IS1000EIS1000EY 01 02 03 Pressure switch with piping adapter Residual pressure exhaust 3 port valve Cross interface
Built-in One-touch Fitting: F (One-touch Fitting), Thread: N (NPT), Accessory: B (Bracket), Tube Size: 03 (Ø5/32 One-touch Fitting), Option: 1 (0.2MPa Setting)
Built-in One-touch Fitting: One-touch Fitting, Thread: NPT, Accessory: Bracket, Tube Size: Ø5/32 One-touch Fitting, Option: 0.2MPa Setting
(Example) 23-R Semi-standard Combinations Available Not available Accessory, Semi-standard Option Symbol 1 1S-1 1S-2 2 3 6 8 R -1 -1S-1 -1S-2 -2 -3 -6 -8 -R 1000 cm3 tank 1000 cm3 (With switch) Bottom limit ON 1000 cm3 (With switch) Bottom limit OFF Metal bowl Lubricator with drain cock Nylon bowl Metal bowl with level gauge Flow direction: Right to left Note) -1, -1S-1 and -1S-2 are with
-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved 1st printing June, 2003 D-YGA P-120 (YG) This catalog is printed on recycled paper with concern for the global environment.
10% or less) IP65 Operating: 0 to 50C, Stored: 25 to 85C (with no condensation and freezing) 1000VAC for 1 min. between external terminal and case 50M (500VDC) between external terminal and case 10 to 500Hz at whichever is smaller: 1.5mm amplitude or 98m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (de-energized) 490m/s2 in X, Y, Z directions 3 times each 1000Vp-p, Pulse width 1s
The ready to send signal (X32) is not turned OFF within 1s after the ABS data request signal (Y42) is turned ON. 2. Programmable PC or Correct the ladder. PLC...etc program incorrect. 3. The ready to send signal (X32) remains OFF for longer than 1s. 3. Faulty programmable PC or PLC...etc output or input module. Change the input or output module. 4.
For driver of 200W to 400W, regenerative resistor is not used. 02:LEC-MR-RB-032 03:LEC-MR-RB-12 Selection of regenerative option 00: Regenerative option is not used For servo amplifier of 100W, regenerative resistor is not used. For servo amplifier of 200 to 400W, built-in regenerative resistor is used. 02: MR-RB032 03: MR-RB12 4 6 4.
Mode button 1s Set button 1s or Mode button 1s Set button 1s B D C Fig. 40 No.DIG-31900-OM002 49 B Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-1 C Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-2 D Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant
When no warning has occurred, RXnA turns OFF within about 1s after power-on. RXnA RXnA Battery warning RXnB turns ON when Open battery cable warning (A92) or Battery warning (A9F) occurs. When no battery warning has occurred, RXnB turns OFF within about 1s after power-on.
When no warning has occurred, RXnA turns OFF within about 1s after power-on. RXnA RXnA Battery warning RXnB turns ON when Open battery cable warning (A92) or Battery warning (A9F) occurs. When no battery warning has occurred, RXnB turns OFF within about 1s after power-on.
)-A 03-A Y510-(02)-A 03-A Y610-03-A (04)-A Y610-(03)-A 04-A 02A VHS40-03A 04A VHS40-06A VHS50-06A 10A Pressure relief 3 port valve Note 6) VHS20-01A 02A VHS30-02A 03A Attachment 02-A E400-03-A 04-A 06-A Piping adapter Note 6) E100-M5-A 01-A E200-02-A 03-A 02-A E300-03-A 04-A E500-06-A E600-06 10 02-A IS10E-4003-A 04-A 06-A Pressure switch with piping adapter Note 6) 01-A IS10E-2002-A
1S-1 1S-2 2 3 6 8 R 1000cm3 tank 1000cm3 (With switch) Bottom limit ON 1000cm3 (With switch) Bottom limit OFF Metal bowl Lubricator with drain cock Nylon bowl Metal bowl with level gauge Flow direction: Right to left Note) 1, 1S-1 and 1S-2 are with metal bowl with level gauge and with drain cock. 1.17-8 AL800/900 Flow Characteristics Precautions RC(PT)2 AL800 AL900 RC(PT)11/4 Be sure to
RUSSIA SMC Pneumatik LLC. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2004 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing IW printing IW 120DN Printed in Japan D-DN This catalog is printed on recycled paper with
DC (+) 1 NC 2 Flow direction DC () 3 OUT 4 8 Digital Flow Switch for Water Series PFW How to order 20 03 27 PFW7 Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Wiring specifications 1l/min=0.0353SCFM 3m lead wire with connector Without lead wire Nil N Thread type Rc NPT G Nil N F Output specifications 27 67 NPN (2 outputs) PNP (2 outputs) Piping port size 03 04 06 3/8 1
2.2 0.19 3.4 1 1 VX3324-03 2.2 0.19 3.4 3/8 (10A) 0.3 VX3234-03 3 0.33 6 0.6 VX3334-03 3 0.33 6 0.15 VX3244-03 4 0.5 9 0.3 VX3344-03 4 0.5 9 Courtesy of Steven Engineering, Inc. !
1500 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance [mm] Distance [mm] 5) 6) Supply pressure 0.4 MPa Consumed flow rate 316 L/min (ANR) Supply pressure 0.5 MPa Consumed flow rate 390 L/min (ANR) 200 200 150 150 2s 1.5s 100 100 50 50 1.5s 1s 0.5s 1s 0.5s 0 0 -50 -50 -100 -100 -150 -150 -200 -200 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350
Max. 2s 2s 1s 1s Min. 0.5s 0.5s 0.2s 0.2s 0.1s 0.1s 0.05s 0.05s 0.02s 0.02s 0.01s 0.01s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 100 125 200 300 400 500 600700 1000 1500 2000 3000 4000 600 5000 7000 Current (% for breaker capacity) Current (% for breaker capacity) For HRS100-A/W-20-B For HRS150-A/W-20-B HRS100-A/W-40, HRS150-A/W-40 4h 2h 1h 30min 20min 14min 10min 6min
specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Rc NPT G Nil N F 3m lead wire with connector Without lead wire Nil N Output specification Port size Size Applicable model Flow rate (l/min) Nil Output specification Applicable model Symbol 10 50 100 200 500 PFA710, 750 PFA711, 721, 751 PFA711, 721, 751 NPN open collector 2 outputs 27 1/8 1/4 3/8 1/2 01 02 03
When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.