Also, use AN110-01 for silencer for pilot EXH. VFR VP7 Individual SUP Style An individual SUP spacer (VV72-P-03, 04) mounted on the manifold-block allows each valve to be supplied individually.
Model VQZ100 VQZ200 VQZ300 AN110-01 AN110-01 AN200-02 AN200-02 AN110-01 Refer to page 4-14-3 for silencer for single valve unit. 4-14-17 18 Series VQZ Option Body Ported External Pilot Specifications Inch-size One-touch Fittings and Option Threads External pilot specifications are used when the operating pressure is below the minimum operating pressure 0.1 to 0.15 MPa or when valve is used
Load factor: ( (Load weight x 9.8)/Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Components VS4 System Solenoid valve Speed controller Silencer Tube bore x Length VQ7 Series VFS2000 AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) A T0604 x 1 m 1 8 Rc EVS Series VFS2000 AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) VFN B T1075 x 1 m 1 4 Rc Double Check Spacer/Specifications Can hold an intermediate cylinder
-01 (Cv = 1.94) 6 x 1m 6 x 1m 8 x 1m AS3001F-08 (Cv = 0.56) 8 x 1m AS3001F-08 (Cv = 0.56) AS3001F-06 (Cv = 0.36) AS3001F-06 (Cv = 0.36) AN101-01 (Cv = 1.11) AN110-01 (Cv = 1.94) 10 x 1m AS4001F-10 (Cv = 0.89) 10 x 1m AS3001F-08 (Cv = 0.56) 12 x 1m AS4001F-10 (Cv = 1.17) 6 x 1m 6 x 1m AS3001F-06 (Cv = 0.36) AS3001F-06 (Cv = 0.36) AN200-02 (Cv = 1.94) AN110-01 (Cv = 1.94) 10 x 1m AS4001F-10
L 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 510.5 EXH port silencer Silencer is installd in the EXH port. 63 38 22 Dimensions 13 Silencer P/N Model VQZ100 VQZ200 VQZ300 AN110-01 AN110-01 AN200-02 AN200-02 AN110-01 2.10-17 Series VQZ Body Ported Option Inch Size One-touch Fittings and Optional Thread
VS7 38 22 Dimensions 13 Silencer P/N Model VQZ1000 VQZ2000 VQZ3000 AN110-01 AN110-01 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP(For VQZ1000/VQZ2000) VVQZ2000-CP(For VQZ3000) Used to block an unused cylinder port when using a 4 way valve as a 3 way valve. 1.12-23 VQZ1000/2000/3000 Body Ported Manifold Option Double check block (Externally placed downstream): For VQZ1000 only VQ1000FPGll
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% System Solenoid valve Speed controller Silencer Tube bore x Length Series VFS2000 AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) A T0604 x 1 m 1 8 Rc Series VFS2000 AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) T1075 x 1 m B 1 4 Rc Double Check Spacer/Specifications Specifications Check Valve Operating Can hold an intermediate cylinder
Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 8 x 1 m AS3301F-08 AN110-01 Series MB/CA2 Series CJ2 Series CM2 4 x 1 m Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AS2301F-04 6 x 1 m 4 x 1 m AS1301F-04 AN120-M5 SYJ5120-M5 SYJ5140-01 AN101
-01 (Nl/min = 1904.1) 6 x 1m 6 x 1m 8 x 1m AS3001F-08 (Nl/min = 549.6) 8 x 1m AS3001F-08 (Nl/min = 549.6) AS3001F-06 (Nl/min = 353.3) AS3001F-06 (Nl/min = 353.3) AN101-01 (Nl/min = 1089.5) AN110-01 (Nl/min = 1904.1) 10 x 1m AS4001F-10 (Nl/min = 873.5) 10 x 1m AS3001F-08 (Nl/min = 549.6) 12 x 1m AS4001F-10 (Nl/min = 1.17) 6 x 1m 6 x 1m AS3001F-06 (Nl/min = 353.3) AS3001F-06 (Nl/min = 353.3
Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP (For VQZ100) This is used when changing piping location.
Note VZ2000-37A-2 For VZ22 AN120-M5 Noise reduction: 18 dB or more (8 x 17l ) AN110-01 Noise reduction: 21 dB or more (13 x 38l ) Description M5 R 1/8 (2) Silencer Note 1) For body ported type Note 2) For sub-plate mounted type 4-15-1 2 Series VZ200 How to Order Option M5 1 2 VZ2 G 1 Foot bracket F Silencer U Foot bracket + Silencer K Series VZ200 Only body ported type Type of actuation
-01 AS2051F-06 AN120-M5 T0604 x 1 m T0806 x 1 m AS3001F-08 T0604 x 1 m T0806 x 1 m AS3001F-08 SX5140-02 SX5120-01 AS3001F-06 AS3001F-06 AN101-01 AN101-01 AS4001F-10 T0604 x 1 m T1075 x 1 m T1209 x 1 m AS3001F-06 T0604 x 1 m AS3001F-06 T1075 x 1 m AS4001F-10 SX7140-03 SX7120-02 SV AS200-02 AN110-01 SZ Conditions [When using SGP (Steel pipe)] Base mounted Series MB Series CS1 SGP10A x 1 m AS420
X Port size) Speed controller System figure System Solenoid valve SYJ7l40-01 Rc(PT)1/8 (S = 12.6mm2) AN110-01 (S = 35mm2) 4 X 1/8 AS2301F-01-04 A 02 03 AS3301F-06 6 X 1/4 B q 02 03 AS3301F-08 SYJ7l40-02 Rc(PT)1/4 (S = 12.6mm2) 8 X 1/4 C AN200-02 (S = 35mm2) 02 03 AS3301F-10 10 X 1/4 D 12 X 1/4 12 X 1/2 AS4001F-12 w E 1.2-53 Series SYJ7000 How to Order Light and surge voltage suppressor
-01 AN200-02 AN200-02 AN200-02 AN110-01 1.12-52 VQZ1000/2000/3000 Base Mounted Manifold Option Double check block (Externally placed downstream): For VQZ1000 only VQ1000FPG Check Valve Operational PrinciplesL l ll Using a 3 position exhaust center valve, this check block can stop and hold a cylinder in mid-stroke.
L 310.5 23 298 22 335.5 25 323 24 360.5 27 348 26 385.5 29 373 28 410.5 31 398 30 435.5 33 423 32 460.5 35 448 34 485.5 37 473 36 39 498 38 40 510.5 EXH port silencer 63 Silencer is installed in the EXH port. 38 22 Dimensions 13 Silencer P/N Model VQZ100 VQZ200 VQZ300 AN110-01 AN200-02 AN200-02 AN200-02 AN110-01 Port plug VVQZ100-CP This is used when changing piping location.
-01 SY3120-C6 SY3140-01 T0806 x 1 m AS3001F-06 T0806 x 1 m AS3001F-08 AS3001F-06 T0604 x 1 m T0604 x 1 m SY5120-01 SY5140-02 AS3001F-08 AN101-01 AN101-01 T1075 x 1 m AS4001F-10 T0604 x 1 m T0604 x 1 m T1075 x 1 m T1209 x 1 m SY7120-02 SY7140-03 AS4001F-10 AS3001F-06 AS3001F-06 AN110-01 AN200-02 T0604 x 1 m T1075 x 1 m T1209 x 1 m T1209 x 1 m AS3001F-06 AS4001F-10 AS4001F-12 T0604 x 1 m T1075
3 1 2 Page 71 Page 72 B port A port DIN rail mounting bracket SS0700-57A-l Double check block (Separated) VQ1000-FPG-ll Silencer (For EXH port) AN200-KM8 Page 71 Page 72 Page 73 SMC AN200 To cylinder port DIN rail mounting bracket External pilot [-R] Double check block (Separated) VQ1000-FPG-ll Blanking plug (For one-touch fitting) KJP-02 KQ2P-23/04/06 Silencer (For manifold EXH port) AN110
Load factor: ( (Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 AS2301F-06 AN110-01 Series MB/CA2 Series CJ2 Series CM2 Series MB/CA2 Body ported Tubing bore x Length Speed controller Silencer Base mounted Tubing bore x Length Speed controller Silencer AN200-02 AN3301F-06 AS1301F-06 6 x 1 m AS3001F-06 SYJ7120-01
Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer AS2051F-06 AN120-M5 AS3001F-06 AN110