SMC Corporation of America
Elite Part Number Search
Search Results "AL40-02-D"

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-14 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C HRL Series 3.3 Installation 3-27 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

Configuration One thermo-chiller for one controller. 2 2 R D R D 3 3 S D S D 5 5 S G S G Controller Master This product Do not connect any wire to other PIN numbers. Fig. 3-13 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.

FLT CH1 abnormal rise in heat exchanger inlet temperature AL40 Compressor Inverter Compressor inverter error AL18 CH1 Press. Sensor CH1 failure of circulating fluid discharge pressure sensor AL41 Compressor Inverter Comm. Compressor inverter communication error AL19 CH1 High Press.

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.

Fig.1-3 shows the location of the communication port. 14 1 Contact input / output signal connector D sub 25 female pin (socket) type 25 13 1 6 Serial communication connector D sub 9 female pin (socket) type 9 5 Fig.1-3 Communication port HRS400-A-46 1.3 Communication port 1-5 DOC1003626 Chapter 1 Read before using 1.4 Touch panel flow Press the [Comm.

Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.

Tightening torque AL20: 0.3 0.05 Nm AL30: 0.4 0.05 Nm AL40 to 60: 0.55 0.05 Nm Flat blade screw driver (Torque driver) Actuators Modular F.R.L.

Tightening torque AL20: 0.3 0.05 Nm AL30: 0.4 0.05 Nm AL40 to 60: 0.55 0.05 Nm Flat blade screw driver (Torque driver) Actuators Modular F.R.L.

Case: [Resin] Polycarbonate Case, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL20-A, AL30-A, AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Sight dome assembly

Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, Type: Damper holding assembly

Case: [Resin] Resin, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, Type: Damper (assembly)

Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Lubrication plug assembly

Case: [Metal] Metal case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: With level gauge, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly